hit counter script
Frigidaire FFAD5033W1 50 Pint Dehumidifier Manual

Frigidaire FFAD5033W1 50 Pint Dehumidifier Manual

Also See for FFAD5033W1:

Advertisement

Frigidaire FFAD5033W1 50 Pint Dehumidifier Manual

Important Safety Instructions

NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the dehumidifier only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.


Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.

Grounding type wall receptacle

(Do not, under any circumstances, cut, remove, or bypass the grounding prong.)
(Power supply cord with 3-prong grounding plug)


For Your Safety

  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
  • Discard water from bucket. Water is not potable and cannot be used for drinking.


Electrical Information

  • For your safety and protection, this dehumidifier is equipped with a three-prong grounding plug on the power cord. Do not, under any circumstances, cut or remove the round ground prong from the plug.
  • Your dehumidifier must be plugged directly into a properly grounded and polarized three-prong receptacle. lf the wall receptacle you intend to use will not accept a three-prong plug, or if you are not sure the outlet is adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper outlet according to the National Electrical Code and applicable local codes and ordinances. Do not use an extension cord or an adapter plug.
  • Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.
  • Do not pinch, bend, or knot the power cord.


Child Safety Precautions

  • Destroy the carton, plastic bags, and any packing materials immediately after the dehumidifier is unpacked. Children should never use these items for play.
  • Do not leave children unattended in an area where the appliance is operating. Do not allow them to sit or stand on the appliance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.

SAFETY PRECAUTIONS

Avoid Serious Injury or Death

  • This dehumidifier contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
  • Do not insert or place fingers or objects into the air discharge area or back grille of the unit.
  • Do not start or stop the dehumidifier by unplugging the power cord or turning off the power at the electrical box.
  • Do not cut or damage the power cord. Do not pull on the power cord.
  • If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
  • In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
  • Do not operate the dehumidifier with wet hands. Do not drink any water from the dehumidifier.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be installed in accordance with national wiring regulations.


Avoid Injury or damage to the unit or other property

  • Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups.
  • Do not climb on or place objects on the unit. Do not hang objects off the unit.
  • Do not place containers with liquids on the unit.
  • Turn off the dehumidifier at the power source when it will not be used for an extended period of time.
  • Operate the unit with air filter in place.
  • Do not block or cover the intake grille, discharge area and outlet ports.
  • Ensure that any electrical/electronic equipment is one yard away from the unit.
  • Do not use or store flammable gases near the unit.

Location & How It Works

Location

Selecting a Location
Selecting a Location

  1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which new moisture-laden air enters the room.
  2. Place dehumidifier in a location that does not restrict the airflow of the air intake and air outlet.
  3. A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
  4. The dehumidifier must be installed on a level floor that will support it with a full bucket of water.
  5. There should be a minimum of 12 inches clearance around the dehumidifier. The unit will produce heat while in operation and should not be operated in an enclosed small space like a closet.

How It Works

When the unit is started, the fan begins to pull moisture-laden air across the dehumidifying coils. The coils condense or draw moisture from the air, and air flows through the air outlet louvers into the room as dry, warm air. Moisture removed from air is collected in a bucket on the front of the dehumidifier.
The unit is designed to operate between 41°F (5°C), and 89°F (32°C). The unit will not work properly if the temperature is out of this temperature range, or the performance of the unit will fall greatly.
The "Compressor" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. Make sure the tank is fitted correctly otherwise unit will not turn on.

Wiring Diagram

Wiring Diagram

Dehumidifier Features & Operating Instructions

Dehumidifier Features

ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and all its functions (as shown below).
Dehumidifier Features

Operating Instructions

Allow the unit to reach room temperature before operating. To begin operating the dehumidifier, follow these steps:

NOTE:
Unit must be upright for one hour prior to operating.

  1. Plug the power cord into a properly grounded 115 volt AC outlet.
    NOTE:
    If the "BUCKET FULL" light is on, remove the bucket and re-install to reset the float switch.
    Operating Instructions Step 1
  2. To turn the unit on, press the ON/OFF button. The unit will run in the factory setting of CONTINUOUS and high fan speed. In the CONTINUOUS mode, the unit will only display CO and not the room humidity. It is recommended you leave the unit running in the CONTINUOUS setting for the first three or four days until the sweating and dampness odors have stopped.
    Operating Instructions Step 2
  3. After a few days when the Relative Humidity has declined, press the HUMIDITY between 35% to 85%, so the room is kept at a comfortable humidity. Pressing the humidity selection in 5% increments. 5 seconds after you have set the desired humidity, the readout will display the actual room humidity. If at any time you want to return to the CONTINUOUS Mode, pressing the HUMIDITY will lower the Relative Humidity through 5% decrements until the display reads CO.
    Operating Instructions Step 3
  4. You can also use the FAN SPEED button to change the fan speed to Hi, Med or Lo. The indicator light will show the setting you have selected. A higher fan speed will result in quicker moisture removal.
    Operating Instructions Step 4
  5. The Filter reset light will illuminate after 250 hours of operation. At this time refer to the care and cleaning section to remove and clean the filter. Once the filter has been cleaned and replaced, simply press the Filter reset button to extinguish the light.
    Operating Instructions Step 5
  6. The TIMER function enables you to either Delay Start or Delay Stop the unit in the choice from 0.5 hour to 24 hours. If the unit is running, then selecting Timer will turn the unit off in the hours that will be set (Delay Stop). If the unit is off, then selecting Timer will turn the unit on in the hours that will be set (Delay Start). TIMER setting: First press TIMER button, then adjust timer setting, by tapping or holding the or button to change the delay timer at 0.5 hour increments, up to 10 hours, then by 1 hour increments up to 24 hours. The control will count down the time remaining (8,7.5,7, etc.) until the unit either starts or stops. For the Delay Start, the fan speed and humidity maintained will be the same as previous setting. After TIMER setting finishes, pressing TIMER button again at any time will stop the TIMER function. The Delay Start/Stop Feature will work until the unit either starts or stops. Once that happens the above steps have to be repeated.
    NOTE:
    1. Before entering TIMER setting, make sure power is being supplied to the unit.
    2. Before entering TIMER setting, make sure pressing HUMIDITY or button sets one desired room humidity first.
      Operating Instructions Step 6
  7. To shut the unit down, press the ON/OFF button.
    Operating Instructions Step 7
    Note: After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.

Fault Codes

  1. If the display reads "AS" or "ES", a sensor has failed. Contact your Authorized Frigidaire Service Center.
    Fault Codes Step 1
  2. If the display reads "EC", check the following operating conditions. Outlet voltage should be 115V±10% and the surrounding temperature should be with in the range of 41°F to 89°F. Unplug the unit and plug it in again under normal operating conditions. If the "EC" code persists, contact your Authorized Frigidaire Service Center.
    Fault Codes Step 2
  3. If the display reads "E4", the communication between display PCB and main control PCB is faulty. Contact your Authorized Electrolux Service Center.
    Fault Codes Step 3

Removing Collected Water

  1. Emptying the Bucket:
    1. When the bucket is full, the unit will shut down and the BUCKET FULL indicator will illuminate.
      Removing Collected Water Step 1
    2. Do not move the unit at this time otherwise water may spill on the floor.
    3. Press sides of bucket gently to unclip the bucket from the unit.
    4. Remove the bucket as shown in the photographs below and empty the bucket.

      Discard water from bucket. Water is not potable and cannot be used for drinking.
      Removing Collected Water Step 2Removing Collected Water Step 3
      Removing Collected Water Step 4
    5. Replace the empty bucket back into the unit and once seated correctly, the unit will start up again.
    6. You should hear a click when the bucket is in the correct position
      If the bucket full light does not extinguish, check that the float is correctly snapped in place.
      Removing Collected Water Step 6
  2. Continuous Drainage:
    1. For continuous drainage operation, you will need a garden hose and a drain nearby to discharge the water into.
    2. Unscrew the drain cap on the back side of the unit. (fig.1)
      Removing Collected Water Fig. 1
      fig. 1
    3. Insert the female threaded end of the hose onto the drain connector of the unit. (fig.2)
      Removing Collected Water Fig. 2
      fig. 2
    4. Screw the garden hose onto the threaded portion of the drain connector. (fig.3)
      Removing Collected Water Fig. 3
      fig. 3
    5. Make sure the hose is secure so there are no leaks.
    6. Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.
    7. Place the end of the hose into the drain. (fig.4)
      Removing Collected Water Fig. 4
      fig. 4
    8. Select the desired humidity setting and fan speed on the unit for continuous draining to start.

NOTE:

  1. Check the seal between the hose and the drain connector. If there is a small leak then replace the hose gasket and re-tighten the hose.
  2. It is recommended that a Dehumidifier Drain Hose - 1/2" (12.7 mm) or larger be used. Make sure there are no kinks or elevations in the hose.
  3. When a hose is not attached to the drain connector, please ensure drain cap is screwed securely to the connector to prevent leakages

Care and Cleaning & Storage

Care and Cleaning

Care and Cleaning

  1. Filter Clean the filter every two weeks based on normal operating conditions. To remove the filter
    1. open the back grille and pull out the filter.
    2. Wash the filter with clean water then dry.
    3. Re-install the filter.
  2. Cabinet
    1. Dust cabinet with an oil-free cloth, or using a damp cloth.
    2. Vacuum grill using brush attachment.
  3. Water Bucket
    1. Clean bucket with warm water and detergent

Storage

Storage
When unit is not in use, unplug and use the cord wrap shown for your model type.

Normal Sounds

  1. Sound of Rushing Air
    At the top of the unit, you may hear the sound of rushing air being moved by the fan.
  2. Dripping Sound
    The sound of dripping water may be heard during the dehumidification cycle.
  3. Gurgle/Hiss
    "Gurgling or hissing" noise may be heard due to refrigerant passing through evaporator during normal operation.
  4. High pitched Chatter
    Today's high efficiency compressors may have a high pitched chatter during the dehumidification cycle.

Before You Call

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

OCCURRENCE SOLUTION

DEHUMIDIFIER DOES NOT OPERATE

Wall plug disconnected. Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected amount of moisture has been removed from the air. If you want to remove more moisture, Select 'CONTINUOUS' by using the humidity button or knob. After the dehumidifier starts, reset the control to the desired setting.
Bucket not installed properly. See "Removing Collected Water".
Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this occurs. Empty bucket and return bucket to position.
Dehumidifier is not turned on. Turn unit on.
"BUCKET FULL" light is on. Remove bucket, empty water and re-install correctly.

DEHUMIDIFIER RUNS TOO MUCH

Windows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside.
Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate.
Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of vacuum O cleaner to clean grill. See "Care and Cleaning". Dehumidifier must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill.
Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the longer the dehumidifier will operate.
Dehumidifier is in the CONTINUOUS mode and will remain on in this mode, use the humidity button or knob to set a RH% higher level.

DEHUMIDIFIER IS OPERATING BUT ROOM IS NOT DRY ENOUGH

Humidity setting is too high. Press the HUMIDITY button or rotate knob to a lower setting or choose CONTINUOUS for maximum dryness.
Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the longer it takes for the room air to become dry.
Dehumidifier does not have sufficient clearance to operate. Air flow to the air outlet is blocked. See "Selecting a Location".
Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below 41°F(5°C). See "Operating Conditions".
Refer to causes under DEHUMlDIFIER RUNS TOO MUCH.

FROST APPEARS ON COILS BEHIND THE FILTER

Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the coil. Frost will usually disappear within 60 minutes.
Room Temperature is too low. All models will operate satisfactorily at temperatures greater than 41°F (5°C).

FAN NOISE

Air is moving through the dehumidifier. This is a normal sound.

If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire Service.

Major Appliance Limited Warranty

Your appliance is covered by a limited one-year warranty for functional repairs only. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions. After one year from your original date of purchase, the consumer will be responsible for diagnostic, labor and parts costs as well as any removal, transportation and reinstallation expenses which are incurred during service on components.

Exclusions
This warranty does not cover the following:

  1. Products with original serial numbers that have been removed, altered or cannot be readily determined.
  2. Product that has been transferred from its original owner to another party or removed outside the USA or Canada.
  3. Rust on the interior or exterior of the unit.
  4. Products purchased "as-is" are not covered by this warranty.
  5. Food loss due to any refrigerator or freezer failures.
  6. Products used in a commercial setting.
  7. Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions.
  8. Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
  9. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
  10. Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, or knobs, handles, or other cosmetic parts.
  11. Surcharges including, but not limited to, any after hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage expense for service calls to remote areas, including the state of Alaska.
  12. Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
  13. Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.

This limited warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.

USA
1.800.944.9044

Electrolux Major Appliances
10200 David Taylor Drive
Charlotte, NC 28262

Canada
1.800.265.8352

Electrolux Canada Corp.
5855 Terry Fox Way
Mississauga, Ontario, Canada
L5V 3E4

2019 Electrolux Home Products, Inc.
All rights reserved.

Brand

Videos

Frigidaire FFAD5033W1 Review Video

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Frigidaire FFAD5033W1 50 Pint Dehumidifier Manual

Advertisement

Need Assistance?

Do you have a question about the FFAD5033W1 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents