Visual inspection of the cabinets' powder coating - look for damage, cracks or
ruptures.
4.2.2 Emergency stop inspection
It is advised to test the emergency button on every occasion a qualified worker of the operator
or service organization visits the location of the charger. This test needs to be performed at
least once a year e.g. during a preventive maintenance round.
Test only when the charger is in idle mode and ready to charge:
1. Press the emergency button.
2. Reset the emergency button by turning the knob clockwise.
4.2.3 Special inspections
In the following cases the charger must be checked by ABB service personnel before further
use:
If it was struck by lightning.
If it is damaged due to an accident or fire.
If its location has been flooded.
4.3
Problem solving
The Site Operator or Helpdesk are the first response to a Customer's call. The Helpdesk can
solve the Customer's simpler issues remotely.
In some cases the Site Operator, present at the location of the charger, can be asked by the
ABB support to report the status of some internal components of the charger. Therefore a
brief description of the positions and functions of these components is presented below.
4.3.1 Overview of the Power Cabinet
A
Door
B
Door handle / lock (unique key for each of the Cabinets)
2 02 1- 0 6- 17
The indicator light (beacon) will turn red.
After a few moments, the charger returns to its idle state.
DUA L D E P OT C HA RGE B OX
WARNING
15 /2 2