LS20-B Maintenance 13. Calibration
13.2 Calibration Procedure
EPSON RC+ has a wizard for calibration.
This section indicates the calibration using the calibration wizard of EPSON RC+.
The same calibration procedure is used for each joint.
The follow the steps below are calibration using Joint #1.
calibrate other joints.
When coordinates for the Manipulator working point require calculation, it is important for
Joint #2 to be calibrated accurately. Execute the procedure in "Calibration Using Right /
Left Arm Orientations" to accurately calibrate Joint #2. For details, refer to Maintenance:
13.3 Accurate Calibration of Joint #2.
When calibrating Joint #4, you must calibrate Joint #3 and #4 at the same time. You cannot
calibrate Joint #4 alone because of the structure of the Manipulator.
If Err9716 or 5016 (Power supply failure of the absolute encoder. Replace the battery.
NOTE
Check the robot internal wiring) occurs, apply the procedure of 13.4 Calibration Procedure
without using Calibration Wizard - 3. Encoder Initialization and then, start the calibration
wizard.
The reference point (a point to check the accuracy) needs to be specified for calibration.
(1) Start the calibration wizard.
332
i.
Select EPSON RC+ 7.0 menu - [Setup] to display the [System Configuration]
dialog.
ii.
Select [Robots]-[Robot**] to display [Calibration].
iii. Select the joint and click the <Calibrate...> button.
Follow the steps below to
LS-B series Maintenance Rev.1