Figures 1. Rear of the appliance with the card slot highlighted..................5 2. Identifying the sections of the rack rails...................... 9 3. Remove the inner rails from both rail kits.....................9 4. Retracting the outer rail..........................10 5. Attaching the sections of the rack inner rails..................... 10 6.
Tables 1. Declared noise emissions in accordance with ISO 9296(1,2,3)............... xiv 2. Cabling requirements for the appliance....................... 5 3. Appliance location considerations........................7 4. Legend for front panel buttons and LEDs....................15 5. Legend for rear panel I/O Ports for the appliance..................17 6.
Page 8
24. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11)............26 25. General specifications (Slicestor 2212A)....................27 26. Power measurements for Slicestor 2212A 32GB RAM w/ 4tb drives (FC:AJ0Y)........27 27. Power measurements for Slicestor 2212A 32GB RAM w/ 6tb drives (FC:AJ0Z)........27 28. Power measurements for Slicestor 2212A 32GB RAM w/ 8tb drives (FC:AJ10)........28 29.
Intended purpose and audience This manual contains the instructions for installing and maintaining this appliance. The audience for this ™ guide consists of those individuals responsible for installing IBM Cloud Object Storage System appliances. Note: • The equipment and device described for installation herein are sophisticated and relatively complex to install.
Suitability for telecommunication environment - This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Examples of a caution and a danger notice. Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229-9054, which is included with your product.
Environmental notices This information contains all of the environmental notices for IBM Systems products in English and other languages. The IBM Systems Environmental Notices information includes statements on limitations, product information, product recycling and disposal, battery information, flat panel display, refrigeration and water-cooling systems, external power supplies, and safety data sheets.
Page 15
Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation;...
Page 22
• Remove any jewelry or metal objects from your body. They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. 4 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Store disk drives at room temperature for at least 2 hours before use. Identify the sections of the rack rails The box contains two rail kits. Each rail kit contains three sections, as shown in the following figure: 8 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Page 27
• The outer rail mounts to the front rack vertical post and rear rack vertical post. • The middle rail allows the outer rail to extend or shorten to accommodate racks of different depths. • The inner rail mounts on the side of the appliance and slides into the outer rail that is mounted on the rack, if wanted.
Page 28
3. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. 4. Align the front tabs of the outer rail with the holes in the rack post, as shown in the following figure. 10 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Page 29
Figure 6. Aligning the outer rails with holes in rack post 5. Push the outer rail into the rack post so that the tabs go through the rack post and hold the rail in place, as shown in the following figure. Figure 7.
Page 30
You might have to depress the locking tabs when inserting. When the appliance is pushed completely into the rack, you can hear the locking tabs click into the locked position. 12 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Page 31
Figure 10. Push chassis into rack 3. Secure the chassis to the rails with the captive M6 thumbscrews on the server. Cable the appliance 1. On the rear panel, connect the C13 end of the power cables to the C14 inlets in the PSU, as shown in the following figure.
The I/O ports are color-coded per the PC 99 specification. The locations of the various I/O ports are shown in the following figure. Figure 14. Rear panel I/O ports for the appliance 16 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Table 5. Legend for rear panel I/O Ports for the appliance Number Description Unused PCIe card slot (on riser card) 10 GbE NIC card Power supply 1 Power supply 2 UID button/LED 1 GbE RJ45 ports (2) 10/100 Mbit/s management port DB-15 video connector USB 2.0 ports (2) Network interface ports...
Page 36
The maximum video resolution is 1600 x 1200 at 75 Hz. USB 2.0 The USB ports can connect a USB keyboard or the supplied USB memory key to any of these connectors. 18 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
A number of components can be replaced in the field. Replacement parts Contact IBM Support for replacement parts for this appliance. The following customer serviceable parts are available: • PSU, RPS, 750 W, 110 - 240 VAC, 12 VDC, FPS •...
The PSUs can be replaced without powering down the appliance. The redundant feature keeps the appliance active while the failed PSU is replaced. 1. Push the release tab on the rear of the PSU, as shown in the following figure. 20 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Figure 18. Removing a PSU from the chassis 2. Pull the PSU out using the provided handle. (The PSU wiring is designed to detach automatically when the PSU is pulled from the chassis). 3. Replace the failed PSU with another PSU. 4.
Page 40
CAUTION: Handle used batteries carefully. Do not damage the battery in any way; a damaged battery can release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Refer to the IBM Systems Environmental Notices for battery disposal guidelines.
47.625 x 83.82 x 17.78 (cm) Weight 157 (lbs) 71.214 (kg) Rail/extended 24/41.5 (in) 60.96/105.41 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 200-240 V AC, FREQUENCY 50-60 Hz 24 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Table 24. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) (continued) 100v 240v 0.83 0.25 START 0.97 0.95 FULL 0.99 0.98 Table 25. General specifications (Slicestor 2212A) S2212A Specification Operating Temperature °C (°F) 10 to 35 degrees °C (50-95 degrees °F) Non - operating temperature °C (°F) -40 to 65 degrees °C (-40-158 °F) Operating humidity...
Table 33. Power measurements for Slicestor 2212A 128GB RAM w/ 10tb drives (FC:AJ11) (continued) 100v 240v START 0.99 0.95 FULL 0.99 0.92 Table 34. General specifications (Manager 3105) M3105 Specification Operating Temperature °C (°F) 10 to 35 degrees °C (50-95 degrees °F) Non - operating temperature °C (°F) -40 to 65 degrees °C (-40-158 °F) Operating humidity...
Dimensions with front bezel (W x D x H) 19.000 x 27.625 x 1.750 (in) 48.26 x 70.1675 x 4.445 (cm) Weight 30.1 (lbs) 13.65313 (kg) Rail/extended 27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) 30 IBM Cloud Object Storage System: Accesser 3105 Appliance Manual...
Table 38. General specifications (Accesser 4105) (continued) A4105 Specification Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 39. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) 0.85 0.26 START 0.92 FULL 0.99...
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks. Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions. Notices 35...