IBM Cloud Object Storage System
Version 3.14.5
Accesser 4105 Appliance Manual
3409-A01/3401-A01/3403-A01
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Accesser 4105

  • Page 1 IBM Cloud Object Storage System Version 3.14.5 Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 2 The information in the IBM Environmental Notices and User Guide (provided on a DVD) This edition applies to IBM Cloud Object Storage System Accesser 4105 and is valid until replaced by new editions. © Copyright IBM Corporation 2016, 2019.
  • Page 3: Table Of Contents

    . 29 Support information ..xvii Chapter 6. Field replaceable units . . . 31 Chapter 1. Accesser 4105 Appliance Replacement parts . . 31 Manual ....1 Replace external front components .
  • Page 4 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 5: Figures

    . 23 Removing a PSU from the chassis . . 32 Final outer rail assembly and mounting Remove the battery . . 33 Push chassis into rack . . 25 Install the battery . 33 © Copyright IBM Corp. 2016, 2019...
  • Page 6 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 7: Tables

    RAM w/ 10tb drives (FC:AJ11) . . 10 Power measurements for Accesser 3105 Power measurements for Slicestor 2212A Power measurements for Accesser 4105 128GB RAM w/ 4tb drives (FC:AJ0Y) . . 10 Cabling requirements for the appliance Power measurements for Slicestor 2212A Appliance location considerations .
  • Page 8 10tb drives (FC:AJ11) . . 38 Power measurements for Accesser 4105 General specifications (Slicestor 2212A) Power measurements for Slicestor 2212A 32GB RAM w/ 4tb drives (FC:AJ0Y) . . 39 viii IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 9: Document Information

    Intended purpose and audience This manual contains the instructions for installing and maintaining this appliance. The audience for this ™ guide consists of those individuals responsible for installing IBM Cloud Object Storage System appliances. Note: v The equipment and device described for installation herein are sophisticated and relatively complex to install.
  • Page 10 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 11: Safety And Environmental Notices

    Suitability for telecommunication environment - This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Examples of a caution and a danger notice. Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229-9054, which is included with your product.
  • Page 12 If IBM supplied a power cord(s) , connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. • Do not open or service any power supply assembly.
  • Page 13 DANGER: Professional movers are to be used for all relocation activities. Serious injury or death may occur if systems are handled and moved incorrectly. (D008) DANGER: Serious injury or death can occur if loaded lift tool falls over or if a heavy load falls off the lift tool.
  • Page 14: Environmental Notices

    Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003) Environmental notices This information contains all of the environmental notices for IBM Systems products in English and other languages. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 15: Declared Noise Emissions

    Note: Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system.
  • Page 16 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 17: Support Information

    Support information Technical support contacts. For more information on the product or help with troubleshooting, contact IBM Support at IBMCloudStorageSupport@us.ibm.com or visit the Directory of worldwide contacts. xvii © Copyright IBM Corp. 2016, 2019...
  • Page 18 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 19: Chapter 1. Accesser 4105 Appliance Manual

    ® Chapter 1. Accesser 4105 Appliance Manual ® The instructions for installing and maintaining the Accesser 4105 appliance. You can download a PDF of this manual. © Copyright IBM Corp. 2016, 2019...
  • Page 20 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 21: Chapter 2. Appliance Safety Precautions

    Be aware of the locations of the power switch on the appliance and the room’s emergency power-off switch, disconnection switch, or electrical outlet. If an electrical accident occurs, quickly remove power from the system. © Copyright IBM Corp. 2016, 2019...
  • Page 22: Electronic Components

    Remove any jewelry or metal objects from your body. They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 23: Chapter 3. Specifications And Requirements

    Dimensions with front bezel (W x D x H) 19.000 x 36.730 x 8.660 (in) 48.26 x 93.2942 x 21.9964 (cm) Weight 282 (lbs) 127.913 (kg) Rail/extended 26/34.5 (in) 66.04/87.63 (cm) Power cord C19/C20 (connector) .5 m (length) © Copyright IBM Corp. 2016, 2019...
  • Page 24: Power Measurements For Slicestor 2584 W/ 6Tb

    -40 to 65 degrees °C (-40-158 °F) Operating humidity 10-80% Non - operating humidity 5-90% Dimensions without front bezel (W x D x H) 17.563 x 33.000 x 7.000 (in) 44.61002 x 83.82 x 17.78 (cm) IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 25: Power Measurements For Slicestor 3448 W/ 4Tb

    Table 7. General specifications (Slicestor 3448) (continued) S3448 Specification Dimensions with front bezel (W x D x H) 18.750 x 33.000 x 7.000 (in) 47.625 x 83.82 x 17.78 (cm) Weight 157 (lbs) 71.214 (kg) Rail/extended 24/41.5 (in) 60.96/105.41 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options...
  • Page 26: General Specifications (Slicestor 2448)

    FULL 1000 0.99 1000 0.98 Table 15. Power measurements for Slicestor 2448 w/ 8tb drives (FC:AJ10) 100v 240v Power(W) Power(W) 0.83 0.25 START 0.97 0.95 FULL 1100 0.99 1040 0.98 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 27: Power Measurements For Slicestor 2448 W/ 10Tb Drives (Fc:aj11)

    Table 16. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) 100v 240v Power(W) Power(W) 0.83 0.25 START 0.97 0.95 FULL 0.99 0.98 Table 17. General specifications (Slicestor 2212A) S2212A Specification Operating Temperature °C (°F) 10 to 35 degrees °C (50-95 degrees °F) Non - operating temperature °C (°F) -40 to 65 degrees °C (-40-158 °F) Operating humidity...
  • Page 28: Power Measurements For Slicestor 2212A 32Gb

    0.99 0.95 FULL 0.99 0.92 Table 25. Power measurements for Slicestor 2212A 128GB RAM w/ 10tb drives (FC:AJ11) 100v 240v Power(W) Power(W) 0.27 0.85 START 0.99 0.95 FULL 0.99 0.92 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 29: Power Measurements For Manager 3105

    Table 26. General specifications (Manager 3105) M3105 Specification Operating Temperature °C (°F) 10 to 35 degrees °C (50-95 degrees °F) Non - operating temperature °C (°F) -40 to 65 degrees °C (-40-158 °F) Operating humidity 10-80% Non - operating humidity 5-90% Dimensions without front bezel (W x D x H) 17.250 x 26.125 x 1.750 (in)
  • Page 30: Power Measurements For Accesser 3105

    Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 31. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) 0.85 0.26 START 0.92 FULL 0.99 0.94 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 31: Power Measurements

    Power measurements The tables that follow show the power measurements for the appliance listed. Table 32. Power measurements for Slicestor 2584 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.17 0.12 START 1200 0.95 1200 0.94 FULL 1700 0.98 1400 0.97 Table 33.
  • Page 32: Power Measurements For Slicestor 3448 W/ 8Tb Drives (Fc:aj10)

    Power(W) Power(W) START 0.83 0.25 0.97 0.95 FULL 1100 0.99 1040 0.98 Table 43. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) 100v 240v Power(W) Power(W) START 0.83 0.25 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 33: Power Measurements For Slicestor 2212A 32Gb Ram W/ 4Tb Drives (Fc:aj0Y)

    Table 43. Power measurements for Slicestor 2448 w/ 10tb drives (FC:AJ11) (continued) 100v 240v 0.97 0.95 0.99 0.98 FULL Table 44. Power measurements for Slicestor 2212A 32GB RAM w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) START 0.27 0.85 0.99 0.95 FULL 0.99...
  • Page 34: Power Measurements For Slicestor 2212A

    100v 240v Power(W) Power(W) START 0.85 0.26 0.99 0.82 FULL 0.99 0.81 Table 54. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) START 0.85 0.26 0.92 FULL 0.99 0.94 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 35: Requirements

    Power Cords Use only the power cords supplied with the appliance. Do not use another type of cord. Do not use extension cords. If additional power cords are required, contact IBM Support. 1000BASE-T Copper Use high quality Category 5e or 5 (CAT5e, CAT5) copper cables.
  • Page 36 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 37: Chapter 4. Install The Appliance Into A Rack

    In multiple rack installations, couple the racks together. 2. Check that the rack is stable before extending an appliance from the rack. 3. Extend only one appliance at a time. Extending two or more simultaneously can destabilize the rack. © Copyright IBM Corp. 2016, 2019...
  • Page 38: Install The Appliance

    The middle rail allows the outer rail to extend or shorten to accommodate racks of different depths. v The inner rail mounts on the side of the appliance and slides into the outer rail that is mounted on the rack, if wanted. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 39: Identifying The Sections Of The Rack Rails

    Figure 2. Identifying the sections of the rack rails Release the inner rail Remove the inner rail from each rail kit, as shown in the following figure. Figure 3. Remove the inner rails from both rail kits 1. Pull on the front release tab to unlock the inner rail from the rail kit. 2.
  • Page 40: Attaching The Sections Of The Rack Inner Rails

    3. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. 4. Align the front tabs of the outer rail with the holes in the rack post, as shown in the following figure. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 41: Aligning The Outer Rails With Holes In Rack Post

    Figure 6. Aligning the outer rails with holes in rack post 5. Push the outer rail into the rack post so that the tabs go through the rack post and hold the rail in place, as shown in the following figure. Figure 7.
  • Page 42: Final Outer Rail Assembly And Mounting

    You might have to depress the locking tabs when inserting. When the appliance is pushed completely into the rack, you can hear the locking tabs click into the locked position. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 43: Rear Of Appliance

    Figure 10. Push chassis into rack 3. Secure the chassis to the rails with the captive M6 thumbscrews on the server. Cable the appliance 1. On the rear panel, connect the C13 end of the power cables to the C14 inlets in the PSU, as shown in the following figure.
  • Page 44 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 45: Chapter 5. Appliance Physical Interface

    Non-maskable interrupt (NMI) button Unused Individual disk activity LED (green) Individual disk status LED (blue/amber) Disk drive 0 Disk drive 1 Unused Unused Unused Unused Unused Unused Asset tag (a pullout mylar tag for customer use) © Copyright IBM Corp. 2016, 2019...
  • Page 46: Rear Panel

    The I/O ports are color-coded per the PC 99 specification. The locations of the various I/O ports are shown in the following figure. Figure 14. Rear panel I/O ports for the appliance IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 47: Network Interface Ports

    Table 58. Legend for rear panel I/O Ports for the appliance Number Description Unused PCIe card slot (on riser card) 10 GbE NIC card Power supply 1 Power supply 2 UID button/LED 1 GbE RJ45 ports (2) 10/100 Mbit/s management port DB-15 video connector USB 2.0 ports (2) Network interface ports...
  • Page 48: Power Supply Led States

    1600 x 1200 at 75 Hz. USB 2.0 The USB ports can connect a USB keyboard or the supplied USB memory key to any of these connectors. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 49: Chapter 6. Field Replaceable Units

    A number of components can be replaced in the field. Replacement parts Contact IBM Support for replacement parts for this appliance. The following customer serviceable parts are available: v PSU, RPS, 750 W, 110 - 240 VAC, 12 VDC, FPS v 2.5"...
  • Page 50: Replace External Rear Components

    7. Restart system and configure the network interface. For more information, see the Appliance Configuration Guide. Battery removal and installation Battery removal To remove the Onboard battery, follow these steps: 1. Power off your system and unplug your power cable. IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 51: Remove The Battery

    Handle used batteries carefully. Do not damage the battery in any way; a damaged battery can release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Refer to the IBM Systems Environmental Notices for battery disposal guidelines. Battery installation To install an Onboard battery, follow these steps: 1.
  • Page 52 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 53: Appendix. Technical Specifications

    Table 64. Power measurements for Slicestor 2584 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.17 0.12 START 1200 0.95 1200 0.94 FULL 1700 0.98 1400 0.97 Table 65. Power measurements for Slicestor 2584 w/ 6tb drives (FC:AJ0Z) 100v 240v Power(W) Power(W) © Copyright IBM Corp. 2016, 2019...
  • Page 54: Power Measurements For Slicestor 2584 W/ 8Tb Drives (Fc:aj10)

    Voltage Range 200-240 V AC, FREQUENCY 50-60 Hz 2 hot-swappable 1100W PSUs in 1+1 configuration Table 69. Power measurements for Slicestor 3448 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 55: Power Measurements For Slicestor 3448 W/ 6Tb Drives (Fc:aj0Z)

    Table 69. Power measurements for Slicestor 3448 w/ 4tb drives (FC:AJ0Y) (continued) 100v 240v 0.28 0.38 0.96 0.94 START FULL 1050 0.99 1050 0.98 Table 70. Power measurements for Slicestor 3448 w/ 6tb drives (FC:AJ0Z) 100v 240v Power(W) Power(W) 0.28 0.38 START 0.96...
  • Page 56: Power Measurements For Slicestor 2448 W/ 4Tb Drives (Fc:aj0Y)

    -40 to 65 degrees °C (-40-158 °F) Operating humidity 10-80% Non - operating humidity 5-90% Dimensions without front bezel (W x D x H) 17.250 x 26.125 x 3.4375 (in) 43.815 x 66.3575 x 8.73125 (cm) IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 57: Power Measurements For Slicestor 2212A 32Gb Ram W/ 4Tb Drives (Fc:aj0Y)

    Table 78. General specifications (Slicestor 2212A) (continued) S2212A Specification Dimensions with front bezel (W x D x H) 19.000 x 27.625 x 3.4375 ( (in) 48.26 x 70.1675 x 8.73125 (cm) Weight 51.75 (lbs) 23.473405 (kg) Rail/extended 27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options...
  • Page 58: General Specifications (Manager 3105)

    43.815 x 66.3575 x 4.445 (cm) Dimensions with front bezel (W x D x H) 19.000 x 27.625 x 1.750 (in) 48.26 x 70.1675 x 4.445 (cm) Weight 29.7 (lbs) 13.471693 (kg) IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 59: General Specifications (Accesser 3105)

    Table 87. General specifications (Manager 3105) (continued) M3105 Specification Rail/extended 27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 88. Power measurements for Manager 3105 100v 240v Power(W)
  • Page 60: Power Measurements For Accesser 4105

    Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 92. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) 0.85 0.26 START 0.92 0.99 0.94 FULL IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...
  • Page 61: Notices

    This information was developed for products and services offered in the US. This material might be available from IBM in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it.
  • Page 62 Statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary.
  • Page 63: Trademarks

    International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 64 IBM Cloud Object Storage System: Accesser 4105 Appliance Manual 3409-A01/3401-A01/3403-A01...