Undo the internal setting screw.
6.
Fit the control knob and heat up the oven for 15
7.
minutes.
Turn the controller to the minimum position.
8.
Remove the control knob.
9.
Adjust the internal adjustment screw until a stable
10.
flame is burning correctly.
If required, loosen the adjustment screw to increase
the gas flow. Tighten the adjustment screw to re-
duce the gas flow. The setting is correct when the
height of the small flame is approx. 3 to 4 mm.
Tighten the adjustment screw in the case of a liquid
connection.
Attach the control knob.
11.
Ensure that the flame does not go out if you quickly
12.
change the gas flow from maximum to minimum
and vice versa, and if you open and close the appli-
ance door.
General nozzle table
Gas type/burner
Natural gas G20/oven burner
Natural gas G20/grill burner
Liquid gas butane/propane G30/
G31/oven burner
Liquid gas butane/propane G30/
G31/grill burner
Nominal operating pressure
Your appliance's nominal operating pressure is:
¡ For natural gas – NG (G20) 20 mbar/2.0 kPa
¡ For liquid gas – LPG (G30) 30 mbar/3.0 kPa
¡ For liquid gas – LPG (G31) 37 mbar/3.7 kPa
You must operate your appliance with these pressure
values. All information on your appliance's rating plate
relates to these pressure values. The manufacturer
mbar
Nozzle
number
20
135 (H1)
20
130 (H3)
28 -
90 (H1)
30/37
28 -
83 (S)
30/37
Replacing grill burner nozzles on appliances with a
grill burner
Undo the screws on the front holder and pull the
1.
burner forwards and out of the gas connection.
On the back wall, the burner is still connected to the
gas supply and the electric ignition.
Carefully place the burner with its front side on the
2.
base of the cooking compartment.
Unscrew the nozzle and replace it with a nozzle that
3.
is suitable for the new gas type.
→ "General nozzle table", Page 25
Replace the label for the gas type with the new label
4.
that is included with the nozzle set.
To install the burner carry out the instructions in re-
5.
verse order.
Bypass
Power in
watts
Gap
3600
3000
58
3600
3000
shall accept no liability for the functionality and power
of your appliance or for other risks id you operate your
appliance with pressure values that differ from those
specified for your appliance.
Note: If you are operating your appliance with liquid
gas, use a gas pressure regulator. The pressure regu-
lator must be connected and maintained by a licensed
expert.
Installation instructions en
Minimum
Maximum consump-
power in
tion
watts
1200
G20: 352 l/h
G20: 298 l/h
1200
G30: 269 g/h
G31: 264 g/h
G30: 218 g/h
G31: 214 g/h
25