Table 35. Summary of SAS chains and enclosures
System
Expansion
ports
Storwize
Port 1 only
V5010E
Storwize
Port 1 and Port
V5030E
Each set of expansion enclosures is connected together sequentially through the IN and OUT SAS ports,
forming a chain with a control enclosure at the end of the chain.
Note: When you connect SAS cables between enclosures, review and follow the guidelines to ensure that
your configuration is valid. Do not begin connecting the cables until you read "SAS cabling guidelines" on
page 67.
Procedure
To install the cables, complete the following steps.
1. Using the supplied SAS cables, connect the control enclosure to the expansion enclosure at rack
position 1, as shown in the following figures.
a) Connect SAS port 1 of the left node canister in the control enclosure to SAS port 1 of the left
expansion canister in the first expansion enclosure.
b) Connect SAS port 1 of the right node canister in the control enclosure to SAS port 1 of the right
expansion canister in the first expansion enclosure.
Figure 67 on page 65 shows how to connect SAS cables on a Storwize V5010E system.
Figure 67. Connecting the SAS cables to a Storwize V5010E system
Figure 68 on page 66 shows how to connect SAS cables on a Storwize V5030E system. In this figure,
two expansion chains are connected to the Storwize V5030E system.
Number of SAS
chains
supported
1
2
2
Control
Expansion
enclosures per
enclosures per
system
chain
1
10
1
10
Chapter 4. Installing the system hardware 65
Maximum
Number of
Enclosures
11
21