Solution 16i
Installation Manual
Comms > MyAlarm >
Email Address
1
Email
Address
Email reporting requires firmware version 2.10 or
i
higher and will only operate within Australia.
Note
This menu allows the installer or master user to program
the email address that the system will send reports to. The
email address can be programmed up to a maximum of
80 characters.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [5] + [5] + [8] + [OK].
The keypad will display the current email address.
3) Use the numeric, [0] to [9], [←] and [→] keys to enter
or change the email address as required.
At any time you can use the [↑] and [↓] keys to scroll
through the complete list of available characters.
To clear all characters from the cursor position to the
right, press the [OFF] key.
4) When the email address is complete, press [OK] to
save and exit, or press [MENU] to exit without saving.
5) To stop email reporting simply remove the email
address or disable all of the email options.
When entering an email address the @ symbol is
i
represented on the keypad display as
Note
this character continually press the 1 key until the
symbol appears.
Comms > MyAlarm >
Email Options
1
Open / Close Reports
2
Zone Alarm Reports
3
Zone Trouble Reports
4
System Reports
5
Access Events
6
Reserved
7
Reserved
8
Reserved
Email reporting requires firmware version 2.10 or
i
higher and will only operate within Australia.
Note
9-16
Comms Programming
EMAiL
-
MENU 5-5-8
Characters
_
To enter
.
E-OPtS
-
MENU 5-5-9
This menu allows the master user to select which event
types will be reported using the email reporting function.
By default the first 4 options are set to report via email.
Follow the procedure below to configure the required
80
options.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [5] + [5] + [9] + [OK].
The keypad will display the current options which are
selected or enabled.
1 2 3 4
3) Use the numeric keys [1] to [8] to turn on and off the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all email options are programmed, press [OK]
to save and exit, or press [MENU] to exit without
saving.
Open / Close Reports
This option allows the control panel to report 'open' and
'close' reports via email.
Zone Alarm Reports
this option allows the control panel to report zone 'alarm'
and 'restore' reports via email.
Zone Trouble Reports
This option allows the control panel to report zone
'trouble' and 'restore' reports via email when a user turns
on an area that has faulted zones.
System Reports
This option allows the control panel to report via email
numerous system reports (e.g. AC Fail, Low Battery etc)
via email.
Access Events
This option allows the control panel to report via email
when a valid token has been swiped or presented.
Y
Y
Y
Y
Y
N
N
N
-bit-