11 TROUBLESHOOTING

Problem
Little or no crema on the top of
the coffee
Sparse coffee dispensing, only
drop by drop
Weak "body"
Foam instead of crema
The orange LED flashes. (3
seconds on - 1 second off)
and the machine stops heating.
The orange LED flashes
(1 second on - 1 second off).
The coffee extraction (pump)
starts for a few seconds, stops
and starts again.
Portafilter/ brew group is
dripping.
Translation of the original German user manual
Possible Cause
The grind is not fine enough
The coffee is too old.
There is too much chlorine in the
water.
The amount of ground coffee is
not enough.
The shower screen is dirty.
The grind is too fine.
There is too much ground coffee.
The grind is not fine enough.
The coffee is old.
The amount of ground coffee is
not enough.
The shower screen is dirty.
The beans are improper.
The setting of the coffee grinder
is not suited for the coffee beans
in use.
ECO mode is activated.
You are in the setup mode
Preinfusion mode is activated.
Portafilter is not fixed properly.
Group gasket is broken.
Troubleshooting
Use a finer grind.
Tamp the ground coffee more
firmly.
Reduce the brewing pressure.
Use fresh coffee
Use a chlorine filter.
Use the right coffee amount
(The marking inside the filter
basket can help you find the right
amount of coffee)
Clean the brew group.
Use a coarser grind.
Tamp ground coffee only slightly.
Increase the brewing-pressure.
Use the right coffee amount
(The marking inside the filter
basket can help you find the right
amount of coffee)
Use a finer grind.
Use fresh coffee.
Use the right coffee amount
(The marking inside the filter
basket can help you find the right
amount of coffee)
Clean the shower screen.
Use another coffee bean.
Adjust the coffee grinder (When
changing the coffee beans,
changing the grind can also be
necessary.)
Operate the brew group lever for
a short time. How to deactivate
the ECO mode is described in
section 6.5.1.
Pull the brew group lever down
and wait 5 seconds.
Deactivate the preinfusion (see
section 6.4.2).
Perform a reset of the machines.
(see section 6.6)
Fix the portafilter properly.
Change group gasket and shower
screen.