hit counter script

Keyboard Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table B-3: Memory Test Error Codes
Error Code
Description
0212-03
Error while restoring test
block
0212-89
ECC error during testing
0214-01
Data error during test
0214-89
ECC error during testing
215
Non-functioning DC-DC
converter for processor X

300-399, Keyboard Test Error Codes

The 300 series of diagnostic error codes identifies failures with keyboard and system
board functions. Corrective action may require replacement of the keyboard or the
system board assembly.
Table B-4: Keyboard Test Error Codes
Error Code
Description
301-XX
Keyboard short test, 8042
self-test failed
302-XX
Keyboard long test failed
303-XX
Keyboard LED test, 8042
self-test failed
304-XX
Keyboard typematic test
failed
HP Servers Troubleshooting Guide
continued
Recommended Action
Replace the Processor Power Module (PPM).
Recommended Action
The following steps apply to error codes 301-XX
through 304-XX:
1.
Check the keyboard connection. If it is
disconnected, turn off the computer, connect the
keyboard, and then retest.
2.
Replace the keyboard and retest.
3.
Replace the system board and retest.