Appendix C: Wake-On-ME Explained

Wake-On-ME, also known as ME WoL, is a feature that allows the ME to go into a low power state when
it is not used. There are three conditions that must be met for Wake-On-ME to function.
The system is in a sleep state: S3, S4, or S5.
ME On in Host Sleep State setting is set to allow ME WoL.
Idle Timeout setting is set to a non-zero value.
The system must be in a sleep state (S3, S4, or S5) for Wake-On-ME to function. If the system is running
(S5), then the ME is also running.
The ME On in Host Sleep State setting must be set to ME WoL so the ME can be put to sleep and
awaken if needed when the system is in a sleep state. The ME counts down from the amount of time set in
Idle Timeout before it will go to sleep.
Idle Timeout must be set to a non-zero value. If it is set to zero, then the Wake-On-ME feature is dis-
abled and the ME will not go to sleep when not being used.
© 2007 Hewlett-Packard Development Company, L.P. The information in this document is subject to change without notice. The
only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or
editorial errors or omissions contained herein.
Microsoft, MS-DOS, Windows, and Windows NT are trademarks of Microsoft Corporation in the U.S. and other countries.
434476-003, 10/2007
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc7800

Table of Contents