hit counter script

Removing And Replacing Consumable And Structural Parts; Removing The Server Top Cover - IBM System x3530 M4 Installation And Service Manual

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

10. Reconnect the SAS signal cables and remote RAID battery cable to the
11. Reinstall the PCI riser-card assemblies with the adapters, if any were installed
12. Reinstall the air baffle (see "Replacing the air baffle" on page 66).
13. Reinstall the cover (see "Replacing the server top cover" on page 67).
14. Reconnect the power cords and any cables that you removed.
15. Turn on the peripheral devices and the server.
Important: Perform the following updates:
v Either update the server with the latest RAID firmware or restore the
v Update the UUID (see "Updating the Universal Unique Identifier (UUID)" on
v Update the DMI/SMBIOS (see "Updating the DMI/SMBIOS data" on page 95).
v If you purchased a Feature on Demand, make sure that you reactivate the

Removing and replacing consumable and structural parts

Replacement of consumable parts and structural parts is your responsibility. If IBM
installs a consumable part or structural part at your request, you will be charged
for the installation.
The illustrations in this document might differ slightly from the hardware.

Removing the server top cover

Attention: If you release the cover latch and remove the cover while the server is
running, the server will lose power and turn off automatically. After you reinstall
the cover, you can power-on the server again.
To remove the server top cover, complete the following steps:
1. Read the safety information that begins on page Safety and "Installation
2. Turn off the server (see "Turning off the server" on page 21) and all attached
3. If the server has been installed in a rack, press the two release latches on the
4. Loosen the two thumbscrews that secure the cover to the rear of the server.
5. Press on the two blue grip points and slide the cover toward the rear; then, lift
362
System x3530 M4 Type 7160: Installation and Service Guide
ServeRAID adapter, if you removed them earlier.
(see "Replacing a PCI riser-card assembly" on page 66).
pre-existing firmware from a diskette or CD image.
page 92).
feature using the instructions in the Feature on Demand documentation.
guidelines" on page 30.
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
front of the server and remove the server out of the rack enclosure.
Attention: Two or more people are required to remove the system from a rack
cabinet.
the cover off the server and set it aside.

Advertisement

Table of Contents
loading

Table of Contents