Sign In
Upload
Manuals
Brands
York Manuals
Air Conditioner
Predator ZF102
York Predator ZF102 Manuals
Manuals and User Guides for York Predator ZF102. We have
2
York Predator ZF102 manuals available for free PDF download: Technical Manual, Installation Manual
York Predator ZF102 Installation Manual (70 pages)
Brand:
York
| Category:
Fan
| Size: 2.99 MB
Table of Contents
Table of Contents
1
General
2
Installation
5
Preceding Installation
5
Unit Shipping Bracket
5
Condenser Covering
5
Compressor Section
5
Limitations
6
Predator ® Component Location (ZF120 Shown)
6
Location
7
Rigging and Handling
7
ZF078-150 Unit Limitations
7
Weights and Dimensions
8
Unit 4 Point Load Weight
8
Unit 6 Point Load Weight
8
Center of Gravity
8
ZF078-150 Unit Accessory Weights
9
Zf078-120
9
ZF078-150 Unit Physical Dimensions
11
ZF078-150 Unit Clearances
11
ZF078-150 Unit Bottom Duct Openings
12
ZF078-150 Unit Electrical Entry
13
ZF078-120 Unit Side Duct Openings
13
Side Duct Dimensions
14
ZF150 Unit Side Duct Openings
14
ZF078-150 Unit Left Duct Opening
14
Ductwork
15
ZF078-150 Roof Curb
15
ZF078-150 Transition Roof Curb
15
Condensate Drain
16
Compressors
16
Side Panels with Hole Plugs
16
Return Downflow Plenum with Panel
16
Discharge Panel in Place
16
Filters
17
Power and Control Wiring
17
Field Wiring Disconnect - Cooling Unit With/Without
18
Field Wiring Disconnect - Cooling Unit with
18
Electric Heat and All Units with VFD Option
18
Gas Heat Without VFD Option
18
Control Wire Sizes
19
Typical Electronic Thermostat Field Wiring
19
Typical Field Wiring 24 Volt Thermostat
19
Electrical Data
20
ZF078-150 Physical Data
28
Optional Electric Heat
30
Electric Heat Minimum Supply Air
30
Optional Gas Heat
31
Gas Pipe Sizing - Capacity of Pipe
31
Side Entry Gas Piping
31
Bottom Entry Gas Piping
31
Gas Heat Minimum Supply Air
32
Options/Accessories
33
Optional Variable Air Volume (VAV)
34
Optional Hot Gas Bypass (HGBP)
36
Standard Economizer and Power Exhaust Set Point Adjustments
36
Enthalpy Set Point Chart
37
Supply Air Limitations
38
Honeywell Economizer Control W7212
38
Belt Adjustment
38
Altitude/Temperature Correction Factors
40
Airflow Performance
41
Airflow Performance - Side Duct Application
42
Zf150
43
Airflow Performance - Bottom Duct Application
44
RPM Selection
45
Air Balance
46
Checking Air Quantity
46
Indoor Blower Specifications
46
Power Exhaust Specifications
46
Dry Coil Delta P
47
Motor Sheave Datum Diameters
48
Operation
49
Cooling Sequence of Operation
49
Additional Static Resistance
49
No Outdoor Air Options
50
Cooling Operation Errors
52
Electric Heating Sequence of Operations
53
Electric Heat Operation Errors
53
Electric Heat Limit Setting 50" Cabinet
53
Gas Heating Sequence of Operations
54
Ignition Control Board
54
Electric Heat Limit Setting 42" Cabinet
54
Electric Heat Anticipator Setpoints
54
Gas Heating Operation Errors
55
Gas Heat Limit Control Settings
55
Start-Up (Cooling)
56
Start-Up (Gas Heat)
56
Gas Heat Anticipator Setpoints
56
Checking Gas Heat Input
57
Gas Rate Cubic Feet Per Hour
58
Gas Heat Stages
58
Charging the Unit
59
Troubleshooting
59
Typical Flame
59
Typical Gas Valve
59
Unit Control Board Flash Codes
60
Unit Control Board Option Setup
61
Option Byte Setup
61
Heat Delay Setup
61
Unit Control Board
61
Heat Delay
62
Ignition Control Flash Codes
62
VAV Control Board Flash Codes
62
Basic Troubleshooting Flowchart
63
Power on Flow Chart
63
Trip Failure Flow Chart
64
Advertisement
York Predator ZF102 Technical Manual (71 pages)
ZF SERIES 6.5 - 12.5 TON 60 Hertz
Brand:
York
| Category:
Air Conditioner
| Size: 4.99 MB
Table of Contents
Description
1
Table of Contents
2
Component Location
2
Cooling with Gas Heat
2
Nomenclature
3
Prior Nomenclature
4
Features and Benefits
5
Standard Features
5
Factory Installed Options
6
Control Options
8
Field Installed Accessories
8
Field Installed Accessories - Non-Electrical
10
Field Installed Accessories - Electric Heat
10
Guide Specifications
11
Field Installed Accessories - Fresh Air
11
Field Installed Accessories - Controls
11
Field Installed Accessories - Electrical
11
Unit Cabinet
12
Indoor (Evaporator) Fan Assembly
12
Outdoor (Condenser) Fan Assembly
12
Refrigerant Components
12
Electric Heating Section
13
Unit Operating Characteristics
13
Additional Factory Installed Options
13
Factory Installed Optional Outdoor Air
13
Other Pre-Engineered Accessories Available
14
Physical Data
15
Physical Data
16
ZF078-150 Unit Limitations
17
Capacity Performance
18
ZF078-150 Cooling Capacities
18
Airflow Performance
28
ZF078-150 Side Duct Application
28
ZF090 (7.5 Ton) Side Duct
28
ZF120 (10 Ton) Side Duct
29
ZF150 (12.5 Ton) Side Duct
29
ZF078-150 Bottom Duct Application
30
ZF078 (6.5 Ton) Bottom Duct
30
ZF090 (7.5 Ton) Bottom Duct
30
ZF102 (8.5 Ton) Bottom Duct
30
ZF120 (10 Ton) Bottom Duct
31
ZF150 (12.5 Ton) Bottom Duct
31
RPM Selection
32
Additional Static Resistance
32
Drive Selection
33
Example Supply Air Blower Performance
33
Table X: RPM Selection
33
Altitude/Temperature Correction Factors
34
Gas Heat Minimum Supply Air
35
Electric Heat Minimum Supply Air
35
Indoor Blower Specifications
35
Power Exhaust Specifications
35
Sound Performance
36
Electric Heat Multipliers
36
Indoor Sound Power Levels
36
Outdoor Sound Power Levels
36
Electrical Data
37
ZF078-150 Standard Motor - Without Powered Convenience Outlet
37
ZF078-150 Standard Motor - with Powered Convenience Outlet
41
ZF078-150 Hi Static Motor - with Powered Convenience Outlet
43
Typical Wiring Diagrams
45
Ytg-J
46
Typical ZF150 Cooling Unit with Gas Heat 208/230 Volt Unit (Options)
52
Typical ZF150 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram
53
Typical ZF150 Cooling Unit with Gas Heat 460/575 Volt Unit (Options)
54
Typical ZF150 Cooling Unit With/Without Electric Heat Wiring Diagram
55
Typical ZF150 Cooling Unit With/Without Electric Heat Unit (Options)
56
BAS Controls Typical Wiring Diagrams
57
Typical SURVEYOR BAS Control Wiring Diagram
57
Typical CPC BAS Control Wiring Diagram
58
Typical HONEYWELL BAS Control Wiring Diagram
59
Typical NOVAR BAS Control Wiring Diagram
60
Weights and Dimensions
61
ZF078-150 Unit Weights
61
Unit 4 Point Load Weight
61
Unit 6 Point Load Weight
61
ZF078-150 Unit Accessory Weights
62
ZF078-150 Unit Dimensions
62
ZF078-150 Unit Physical Dimensions
63
ZF078-150 Unit Clearances
64
ZF078-150 Unit Bottom Duct Opening
65
ZF078-150 Unit Electrical Entry
66
ZF078-120 Unit Side Duct Openings
66
ZF150 Unit Side Duct Openings
67
ZF Side Duct Dimensions
67
ZF078-150 Unit Left Duct Opening
67
ZF078-150 Unit Accessory Dimensions
68
ZF078-150 Roof Curb
68
ZF078-150 Transition Roof Curb
68
Compressors
68
Economizer Options
69
Economizer Usage
69
Economizer Downflow W/Power Exhaust
69
Johnson Controls Unitary Products
69
Economizer End Return W/Power Exhaust
70
Field Installed Horizontal Economizer W/Power Exhaust
70
Advertisement
Related Products
York ZF 180 Series
York Predator ZF120
York Predator ZF150
York ZF 240 Series
York ZF SERIES
York ZF076
York Predator ZF078
York ZF072
York PREDATOR DM 090
York PREDATOR DM 150
York Categories
Air Conditioner
Heat Pump
Chiller
Furnace
Air Handlers
More York Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL