SYMPTOM
Intermittent igniter sparking
More than four clicks of
igniter before lighting
Constant igniter sparking
Igniters sparking but no
flame ignition.
Rangetop will not operate
(lights and surface burners
will not come on)
Foods in oven are not
cooking sufficiently.
English 26
POSSIBLE CAUSE
Ceramic igniter is wet or dirty.
Burner ports are clogged.
Improper fit of burner cap onto
burner base.
Range is not properly grounded.
Electrical power supply is incorrectly
polarized.
Gas supply valve is in "OFF"
position.
No power to the unit.
Improper cookware.
Appliance not level.
REMEDY
Carefully dry or clean igniter.
Clean ports on burner cap with a wire, a
needle or straightened paper clip.
Align burner cap properly on burner
base.
Refer to the Installation Manual. Have a
qualified electrician ground the range
properly.
Restore gas supply to the unit.
Check for open circuit breaker.
Check that power supply line connection
is connected to the proper voltage.
Refer to Cookware Recommendations in
the Use and Care Guide.
Refer to the Installation Manual for
instructions on how to level the
appliance.