Expansion Card Functions
"P" parameters will be appeared when the expansion option is connected.
Func.
Name
Code
P001
Reaction when
option card error
occurs
P003
[EA] terminal
selection
P004
Pulse train input
mode selection for
feedback
P011
Encoder pulse
setting
P012
Simple positioning
selection
P014
*2
Creep pulse ratio
p015
Creep Speed
P017
*2
Positioning
completion range
P026
Over-speed error
detection level
P027
Speed deviation
error detection
level
P031
Deceleration time
Input Type
P033
Torque command
input selection
P034
Torque command
level input
p036
Torque bias mode
selection
p037
Torque bias value
setting
p038
Torque bias polar
selection
"P" Function
Description
Two option codes:
00...Inverter trips
01...Ignores the error (Inverter continues
operation)
Three option codes:
00...Speed reference (incl. PID)
01...For control with encoder feedback
02...Extended terminal for EzSQ
Four option codes:
00...Single-phase pulse [EA]
01...2-phase pulse (90° difference) 1
([EA] and [EB])
02...2-phase pulse (90° difference) 2
([EA] and [EB])
03...Single-phase pulse [EA] and
direction signal [EB]
Sets the pulse number (ppr) of the
encoder, set range is 32 to 1024 pulses
Two option codes:
00...simple positioning deactivated
01...simple positioning activated
0.0 to 400.0[%]
Set range is start frequency (b082) to
10.00 Hz
0 to 9999. /1000 (10000) [pulse]
Set range is 0 to150%
Set range is 0 to 120 Hz
00...Operator
01...EzSQ
Three option codes:
00...Analog voltage input [O]
01...Analog current input [OI]
03...Operator
06...Option
Set range is 0 to 200%
Two option codes:
00...No bias
01...Operator
05...Option
Range is –200 to 200%
Three option codes:
00...According to the sign
01...According to the rotation direction
91
Defaults
A
B
Initial data
00
00
00
512
00
125.0
5.00
50
115.0
10.00
00
00
0.
00
0.
00
Units
−
−
−
−
−
%
Hz
Pulses
%
Hz
−
−
%
−
%
−