General Fault Codes (Continued)
Code /
Icon
S: 36
*
Unable to start microwave module.
S: 37
*
Measurement hardware problem.
S: 38
*
Microwave module hardware fail-
ure: unable to calculate distance
measurement.
S: 43
*
Factory calibration for the radar
receiver has been lost.
S: 45
*
No valid boot program detected:
firmware corrupt.
S: 48
*
User configuration is invalid. One or
more of parameters: Low Calibration
Point, High Calibration Point, and/or
Auto False-Echo Suppression, are
set to invalid values.
S: 49
*
EEPROM corrupt.
S: 50
*
EEPROM corrupt.
S: 51
*
EEPROM corrupt.
Page 88
SITRANS LR260 (HART) – INSTRUCTION MANUAL
Meaning
Cycle power. If fault persists, contact
your local Siemens representative.
Cycle power. If fault persists, contact
your local Siemens representative.
Cycle power. If fault persists, contact
your local Siemens representative:
repair required.
Repair required: contact your local
Siemens representative.
Repair required: contact your local
Siemens representative.
Reconfigure the unit. Ensure the dif-
ference between High Calibration
Point and Low Calibration Point is
not less than or equal to zero; do a
master reset.
Repair required: contact your local
Siemens representative.
Repair required: contact your local
Siemens representative.
Repair required: contact your local
Siemens representative.
Corrective Action
7ML19985KE02