Table 15-8 Wait Time after P Bit Setting
Item
Wait time after P bit setting
Note: * Additional programming processing is necessary only when the reprogramming loop count
(n) is 1 to 6.
6. The program/program-verify flowchart for the H8/3022F is shown in figure 15-11.
To cover the points noted above, bits on which reprogramming processing is to be executed,
and bits on which additional programming is to be executed, must be determined as shown
below.
Since reprogram data and additional-programming data vary according to the progress of the
programming procedure, it is recommended that the following data storage areas (128 bytes
each) be provided in RAM.
Table 15-9 Reprogram Data Computation Table
Result of Verify-Read
after Write Pulse
(D)
Application (V)
0
0
0
1
1
0
1
1
Legend:
D: Source data of bits on which programming is executed.
X: Source data of bits on which reprogramming is executed.
462
Symbol
t
When reprogramming loop count (n)
SP
is 1 to 6
When reprogramming loop count (n)
is 7 or more
In case of additional programming
processing*
(X)
Result of
Operation
Comments
1
Programming completed: reprogramming
processing not to be executed
0
Programming incomplete: reprogramming
processing to be executed
1
1
Still in erased state: no action
Symbol
t
sp30
t
sp200
t
sp10