hit counter script

Learn Flow/Current - Rain Master DX3 User Manual

Hide thumbs Also See for DX3:
Table of Contents

Advertisement

RAIN MASTER
®

Learn Flow/Current

For the DX3 controller to issue meaningful alerts when there is a flow or current
problem, the proper flow and current rates must be "learned" by the system. The
Learn Flow/Current command therefore teaches the DX3 system the nominal (ideal)
current and flow settings to each valve and station. One would typically activate the
Learn command for either a new system or when a when a new flow meter has been
installed.
Setup Learn Flow/Current
Setup Learn Flow/Current
Learn Flow/Current
The Learn Flow/Current command consists of three screens:
Current %'s: Setup the Nominal Current limits. Use the Control Dial to switch
between and adjust the Upper and Lower Limit fields. Recommended value for Upper
Limit and Lower Limit is 30% for both.
Flow %'s: Setup the Nominal Flow limits. Use the Control Dial to switch between
and adjust the Upper and Lower Limit fields. Recommended value for Upper Limit
and Lower Limit is 20% for both.
Use the Control Dial to activate the Learn Flow/Current command, triggering the
3rd screen above.
If the "All Satellites" check box is checked, the learn function will be performed
on the submaster and all connected satellites.
32
|Current %
|Flow % |
% of Nominal Current:
Upper Limit %:
Lower Limit %:
Learn Flow/Current
|Current %
|Flow % |
% of Nominal Flow:
Upper Limit %:
Lower Limit %:
Learn Flow/Current
Start Now All Satellites
Delay Learn Until
09:12AM
Include Current
Include Flow
Status: Off
Flow: 0 (GPM)
Cur: 0.01
Chapter 5: Setup
DX3 User Manual
WED 5:43:40 PM
005
005
WED 5:43:40 PM
005
005
WED 5:43:40 PM
02/10/17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents