Flow Max Warnings and Exception Conditions

All warnings referenced in this section are described fully in Chapter 9: Alerts. Please
refer to that section for details. Most exception conditions result in warnings being
generated at the submaster as well as each Flow Max participant.
Different information however will appear at different controller locations depending
upon the circumstances.
Flow Max Lower Limit Violation
The submaster has determined that the measured flow from the flow meter(s) is less
than the expected flow. All station run times associated with the (low) flow reading
will be terminated. Programs automatically advance to their next scheduled station.
Flow Max Upper Limit Violation
The submaster has determined that the measured flow from the flow meters(s) is
greater than the expected flow. All station run times associated with the (high) flow
reading will be terminated. Programs automatically advance to their next scheduled
station.
Flow Max Communications Failure
The hardwire data communications between the submaster and one or more
satellites has been lost or interrupted. This may be indicative of a failure of the
communications cable which runs to/from each satellite in a Flow Max configuration.
All irrigation is terminated.
Flow Max Main Flow
The main line limit for the Flow Max system has been exceeded. All irrigation is
terminated and all future scheduled irrigation will be inhibited.
Flow Max Unscheduled Flow
Flow was detected but no controllers within the system had any stations which were
turned on. The normally open master valve will be energized and all future scheduled
irrigation will be inhibited.
Appendix D: Setting Up a FLOW MAX System
120
DX3 User Manual