Mechanical specifications
Material
Silicone-free
Color
Antenna material
Type of antenna
Printing
Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
Shock-resistant according to DIN EN 60721-3-7,
Class 7 M3
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (L x W x D)
Weight
The information relates to the maximum read range. You will find more information on
1)
ranges in the section "Minimum distances and maximum ranges (Page 55)".
The values for shock and vibration are maximum values and must not be applied
2)
continuously.
Note
Effects of temperatures > 70 °C
Note that in temperature ranges > 70 °C, the transponder can become slightly deformed.
However, this has no effect on the transponder function.

SIMATIC RF600

System Manual, 06/2019, J31069-D0171-U001-A22-7618
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
PVC
Yes
White
Aluminum
Shortened dipole
Can be printed using heat transfer technique
-25 ... +85 °C
-40 ... +85 °C
-40 ... +85 °C
Not suitable for mounting directly on metal
IP67
Torsion and bending stress conditionally permis-
sible
100 g
2)
50 g
2)
86 × 54 × 0.6 mm
3 g
Transponder
7.5 SIMATIC RF610T
6GT2810-2BB80