Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
Shock-resistant according to DIN EN 60721-3-7,
Class 7 M3
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (∅ × D)
Weight
Type of mounting
Standards, specifications, approvals
MTBF
The range is reduced to 70% at the band limits 902 MHz or 928 MHz. Due to frequency
1)
fluctuations, this effect has no impact.
Mounting on a flat metal surface with a diameter of at least 150 mm and at room
2)
temperature. The information relates to the maximum read range. You will find more
information on ranges in the section "Minimum distances and maximum ranges (Page 55)".
When these minimum distances are not achieved, there is a reduction in the maximum
possible read and write distances of the transponder.
The values for shock and vibration are maximum values and must not be applied
3)
continuously.
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
In operation, during write/read access
•
In operation, outside write/read access
•
During transportation and storage
•
6GT2810-2EE0x
-25 ... +85 °C
•
-40 ... +125 °C
•
-40 ... +125 °C
•
0 mm
Designed for mounting directly on metal
IP68 / IPx9K
Torsion and bending stress is not permitted
100 g
3)
50 g
3)
30 × 8 mm
6 g
1 x M3 countersunk screw
≤ 0.5 Nm
1141 years
Transponder
7.8 SIMATIC RF625T
411