15. Turn the fuel shut-off valve to the "on" position (Fig.
370).
Fig 370
16. Connect the green oil sending wire to the oil
pressure switch (Fig. 371).
Fig 371
Z Master Z400 Service Manual
17. Reconnect the throttle cable:
a. Position the throttle control lever so that there is
approximately 1/2" (12.7mm) between the lever
and the full throttle position of the throttle slot
(Fig. 372).
PICT-0406
b. Reconnect the z-bend of the throttle cable to
the throttle linkage (the top hole of the throttle
plate). Pull the throttle linkage all the way to the
right and hold it in the wide open throttle (WOT)
position. Install and tighten the cable clamp
(Fig. 373).
PICT-0404
ENGINE
Fig 372
PICT-0293
Fig 373
PICT-0420
5