11
6. Sample Vessel Installation
6.1 Variable pressure/constant volume cylinders.
Spun cylinders may be installed in a horizontal position
on the DynaPak BackRack vessel rack. Avoiding traps
in the line, install stainless steel tubing and fittings from
the sample discharge port of the sampler to the product
end of the sample cylinder.
300cc and 500cc spun cylinders may also be installed
in a vertical position. Piping from the sampler discharge
port to the sample vessel should be arranged so that
liquid traps are not created.*
6.2 Variable volume/constant pressure cylinder.
The free-floating piston cylinder (DuraSite) may be
installed in a horizontal position on an optional vessel
rack. Free-floating piston cylinders should NOT be
installed on the DynaPak BackRack vessel rack.
Install 1/8" tubing from the sample discharge port of the
manifold to the product end of the vessel. Avoid traps in
this line.
See diagram #10 for DuraSite portable sample vessel
instructions.
6.3 LinkPlus. Install the optional LinkPlus directly into
the sample discharge port of the sampler. Use
stainless steel tubing and fittings to connect the
LinkPlus outlet to the product end of the sample
cylinder.
*Standard configuration for this option package.
YZ
Systems,
Inc.
•
3101
Pollok
Drive
•
Conroe,
Texas
•
USA
•
77303
•
P:
936.788.5593
•
F:
936.788.5720
DP-2010H Version 06222001 ATEX Rev.