hit counter script

Siemens SIMATIC RF610R System Manual page 119

Hide thumbs Also See for SIMATIC RF610R:
Table of Contents

Advertisement

D D esign, dimensions and weight
Dimensions (W × H × D)
Weight
Type of mounting
Operation indicator
Status display
S S tandards, specifications, approvals
Proof of suitability
MTBF
1)
2)
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
EN 60950). All voltage sources must meet the requirements of limited power sources (LPS) and
NEC Class 2.
Note that, depending on the power consumption, using extension cables > 20 m (6GT2891-
4FN50) may lead to a voltage drop on the reader. This voltage drop can mean that the necessary
minimum voltage on the reader is below the required 20 V.
The values for shock and vibration are maximum values and must not be applied continuously.
These values only apply to mounting using screws.
140.5 × 133 × 45 mm
370 g
VESA 100
4x screws M4 ( 1.5 Nm)
6 LEDs
1 LED (enclosure, all-round)
EN 301 489-1 V2.2.0 / EN 301 489-3 V2.1.1 / EN
302 208 V3.1.1
FCC CFR 47, Part 15 section 15.247
29 years
Readers
5.2 SIMATIC RF610R
6 6 GT2811- - 6 6 BC10- - x x AA0
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf600Simatic rf615r

Table of Contents