L L imitations in the USA and Canada
Note
L L imitation of the radiated power (FCC)
RF600 systems that are put into operation in the USA and Canada must not exceed the
following radiated power with an RF615A antenna:
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
P (dBm)
Limitations in China
Note
L L imitation of the radiated power (CMIIT)
RF600 systems that are put into operation in China must not exceed the following radiated
power with an RF615A antenna:
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
4000 mW EIRP (or 36 dBm EIRP)
Conducted power P (dBm) of the RF600 reader: < 30 dBm
Antenna gain G
(dBi) in the FCC frequency band:
i
Cable loss a
(dB):
1 dB
k
30 dBm - (G
- 6 dBi) + a
i
2000 mW ERP (or 33 dBm ERP)
Converted into EIRP: 3250 mW EIRP (or 35 dBm EIRP)
Radiated power:
2000 mW ERP (or 33 dBm ERP)
Converted into EIRP:
Use of cable loss associated with the antenna cable.
k
3250 mW EIRP (or 35 dBm EIRP)
6.2 SIMATIC RF615A
-5 dBi
Antennas
237