4. To set the PG position to the "5" position, turn the PG Cam on the right end of the Carriage Shaft counter
clockwise (CCW) so that the point marked "5" faces down.
5. With the conductor connection portion of the adjustment gauge up, set the gauge in the specified position (on
the left side of the Front Paper Guide Assy).
Setting Position
Rear direction: Align the rear end of the gauge with the Driven Roller Shaft of the Upper Paper Guide Assy.
Left direction: Align the left end of the gauge as shown in
6. Move the CR Unit onto the adjustment gauge.
 Moving position
Align the left end of the gauge with the left end of the CR Unit.
7. To set the PG position to "0", turn the PG Cam on right end of the Carriage Shaft clockwise (CW) so that the
point marked "0" faces down. (See
 PG standard value
• PG position "0":
 Adjustment resolution:
Adjustment
Figure 2-17. PG Cam Position
130-digit side
Adjustment gauge
Figure 2-18. Setting the Adjustment Gauge
Figure
2-17.)
1.05 mm - 1.25 mm
0.06 mm
Details of Adjustments
PG Cam
Figure
2-18.
CR Unit
SE Group Confidential (Related Staff Only)
Revision D
51