● No-contact (transistor)
Withstand voltage:
Maximum drive current: 6 mA or more
Residual voltage:
Leakage current:
Drive method:
● Contact signal
Use chattering of 2.0 ms or less to switch the contact on/off.
4.3.3.1. Print Stop Signal
The print stop signal provides a function to prevent printing from the outside.
Note that the ready to print output signal does not change even when this signal is input from the outside.
Input ON: The IJ Printer in the ready state does not print characters even if the print target detector is turned
on. However, if printing is in progress in the IJ Printer, it cannot be interrupted.
Input OFF: The IJ Printer in the ready state prints characters even if the print target detector is turned on.
● The ON state indicates the low signal level and the OFF state the high signal level.
● The tracking function is unavailable. In tracking mode, the print stop signal cannot be used to specify the
timing of print stop.
● When [Repeat print] is set, repeat printing operates according to the start print signal created inside the IJ
Printer.
48
30 VDC or more
2 V or less
0.1 mA or less
Open collector