hit counter script
Honeywell HPA830 - Designer Series HEPA Air Purifier Manual

Honeywell HPA830 - Designer Series HEPA Air Purifier Manual

Also See for DESIGNER HPA830 Series:

Advertisement

Honeywell HPA830 - Designer Series HEPA Air Purifier Manual

If you have any questions about the operation of this product, please contact us:
1-800-477-0457
ConsumerRelations@HelenofTroy.com,
www.HoneywellPluggedIn.com

ASSEMBLING THE LEGS ONTO THE AIR PURIFIER

Before proceeding, install the legs included in the bottom of the package. Insert each leg into the hole at the bottom of the Air Purifier making sure to align the leg so it points outward. Insert each leg all the way until you feel it set into place.
ASSEMBLING THE LEGS ONTO THE AIR PURIFIER

GETTING TO KNOW YOUR AIR PURIFIER

GETTING TO KNOW YOUR AIR PURIFIER

  1. Aromatherapy Tray cover
  2. Air Outlet & Control Panel
  3. Main Body
  4. Air Quality Indicator Light
  5. Legs
  6. Pre-Filter & HEPA Filter
  7. Grille Cover

CONTROLS AND FEATURES

CONTROLS AND FEATURES

  1. Air Outlet Grille
  2. Aromatherapy Essential Oils Tray
  3. Filter Check/Reset & Indicator Light
  4. Cleaning Level & Indicator Light
  5. Auto Mode & Indicator Light
  6. Sleep Mode & Indicator Light
  7. Power Button & Indicator Light

AIR QUALITY INDICATOR

The built-in VOC sensor constantly monitors room air quality.

The Air Quality Indicator Light on the bottom of the Air Purifier will illuminate the floor below it with the current room air quality level:
Green=Good Yellow=Moderate Red=Poor
AIR QUALITY INDICATOR LIGHT

FILTRATION

The Honeywell Designer Series Air Purifier delivers proven HEPA performance with an odor fighting Pre-Filter, Certified Honeywell HEPA Filter and an UltraQuiet motor.

GETTING STARTED

  1. Ensure that the unit is powered off and unplugged.
    GETTING STARTED
  2. Select a firm, level, and flat location. Ensure the unit is more than 6 inches away from the closest wall or furniture so that the grille is not blocked. Portable air purifiers are more effective in rooms where all doors and windows are closed.

    NOTE: If the unit is placed on a light-colored carpet, a small mat or rug should be used underneath to prevent staining. This is especially important in homes with contamination from smoking, fireplaces, or where candles are burned.
  3. Remove the filter grille cover by grasping the recess in the top center of the grille cover and pulling forward.
  4. Remove the round filter cartridge from the air purifier by pulling on the tab on the top of the filter. This cartridge contains a wrapped HEPA Filter and wrapped Pre-Filter.
  5. Remove protective plastic wrap from Filter(s).
  6. Wrap the Pre-Filter around the HEPA Filter cartridge and secure it with the fasteners provided.
  7. Place the Filter(s) back into the air purifier housing, making sure the plastic ring is at the top and the tab faces out.
  8. Replace the filter grille cover by placing the tabs on the bottom of the grille into the slots on the unit. Gently push the top of the grille until secure.

OPERATION

  1. Ensure that the plastic wrap has been removed from the filters and the filters are replaced in the unit. Next, plug the power cord into a working electrical outlet.
  2. another cleaning level is selected. Tap Power Button to turn on the air purifier. The air purifier will start automatically on Auto Mode until
  3. To shut off, tap the Power Button once.
  4. Use the Cleaning Level button to choose a different cleaning level.
    QUIET CLEAN: quietest setting and optimized to capture the smallest particles.
    GENERAL CLEAN: recommended for dust and general, everyday air cleaning.
    ALLERGEN: optimizes allergen capturing performance.

Sleep Mode


Pressing the SLEEP MODE button sets the unit to the lowest cleaning level for ultra-quiet nighttime operation while dimming control panel LEDs to 10% and completely turns off the Air Quality Indicator light.

Automatic Cleaning Mode & Air Quality Indicator


When the Auto mode is activated, the air purifier will automatically operate at the appropriate cleaning level to reduce the VOCs that are detected in the room. To select this mode, tap the Auto button and the Auto Mode light will illuminate to indicate the setting has been activated.

This air purifier is equipped with a VOC Sensor that detects the level of VOCs in the room and provides a visual display to indicate air quality. The Air Quality Indicator color display is located at the bottom of the air purifier. The VOC Sensor is constantly monitoring the air and the Air Quality Indicator light will illuminate the floor either green, yellow, or red depending on the level of VOCs detected in the room:

Green – Good air quality. There is a low level of VOCs detected.
Yellow – Moderate air quality. There is a moderate level of VOCs detected.
Red – Poor air quality. There is an elevated level of VOCs detected.

VOCs are gases that are emitted from certain household cleaning, home improvement, and even common home decor products. These gases can be irritating if inhaled.

NOTE: Upon start up, the unit may take a few minutes to calibrate and measure the air quality. During this time, the Air Quality Indicator will pulse between green, yellow, and red until the air quality is determined. When the appropriate reading is determined, the indicator will then remain a solid color.

Filter Check/Reset


This air purifier model has a Filter Check Light to remind you when it is time to replace the Pre-Filter and HEPA Filter based on the air purifier's hours of use.

When the Filter Reset Light illuminates, it is time to replace the Pre-Filter.

When the Filter Reset Light blinks every 2 seconds, it is time to replace the HEPA Filter.

For more detailed information, see the next section.

REPLACEMENT FILTERS

To help ensure stated product performance, use only Genuine Honeywell Replacement Filters

You can purchase Genuine Honeywell Replacement Filters at the retailer where you purchased your air purifier or order directly from www.HoneywellPluggedIn.com

REPLACEMENT FILTERS

When the Filter Reset Indicator Light illuminates or blinks, it is time to replace one or more of the filters.

FILTER CHECK/ RESET LIGHT FILTER WHEN TO REPLACE NUMBER OF FILTERS NEEDED
Solid Illumination
(not blinking)
Honeywell Pre-Filter

HRF-AP1 or HRF-APP1
Every 3 Months 1 Pre-Filter
Blinks every 2 seconds Honeywell HEPA Filter

HRFJ830
Every 12 Months 1 HEPA Filter

To change either filter, remove the filter cartridge. See the Getting Started section for filter removal and replacement instructions.

To change either filter, follow the steps described below:

  1. Remove the HEPA Filter and Pre-Filter Pre-Filter cartridge from the Air Purifier.
    Remove fasteners holding the Pre-Filter and remove the Pre-Filter from the HEPA Filter cartridge. Cut a new Pre-Filter from the Universal HRF-AP1 Pre-Filter using the old Filter as a template (5.7 in x 22.5 in). If also replacing the HEPA Filter, discard the used HEPA Filter but keep the Pre-Filter fasteners to use on the new HEPA Filter.
  2. Wrap the new Pre-Filter around the HEPA Filter cartridge and secure it with the fasteners provided.
  3. Reinsert assembled filter cartridge into the Air Purifier. Ensure the plastic ring is on the top with the tab facing out.

These replacement intervals are intended as guidelines only. Performance of any filter media is dependent upon the concentration of contaminants going through the system. High concentrations of contaminants such as dust, pet dander, and smoke will reduce the useful performance of the filters.

NOTE: The Pre-Filter and HEPA Filters are not washable and should not be vacuumed. DO NOT immerse them in water.

RESET FILTER CHECK INDICATOR

After you have replaced the appropriate filters, plug the unit back in. The Filter Reset Light will remain on or blinking until it is reset.


To reset the Filter Check/Reset Light:

With the unit powered ON, press and hold the Filter Reset button for 3 seconds until light turns off or stops blinking. The light will stay off until the next filter needs replacing.

NOTE: This procedure is the same whether you are resetting the Pre-Filter or HEPA Filter Reset Light.

USING THE AROMATHERAPY TRAY

This Designer Series Air Purifier features an Aromatherapy Tray (Essential oils not included).
Follow the steps below to use the Aromatherapy feature on your Designer Series Air Purifier.

Add Essential Oil to the Aromatherapy Tray:

  1. Open the cover of the Aromatherapy Tray.
  2. Place cotton ball or other absorbing material (not included) into the tray.
  3. Add a few drops of your favorite essential aroma oils (not included) onto the material.
  4. Once essential oils have been added, replace the cover by aligning the larger tab with the large slot and then pressing down until it snaps in place.

Aroma will be infused with the cleaner air being returned back into the room while the unit is in use.

Note: The use of scented aromatherapy oil may trigger the VOC to illuminate yellow or red under the unit and cause the unit to operate at a higher speed on AUTO mode.

CLEANING THE AROMATHERAPY TRAY

The aromatherapy tray can be removed from the unit for easier cleaning.

  1. To clean the aromatherapy tray, remove the aromatherapy tray cover, and discard the absorbent materials or cotton.
  2. Twist the essential oils tray counter-clockwise (to the left) until it loosens, then lift it out of the unit.
  3. Wipe down the tray and wash it under clean tap water until it is clean.
  4. Insert clean essential oils tray and replace into the unit by aligning the tabs and twisting clockwise (to the right).
  5. Add new cotton or other absorbent material and add a few drops of essential oils if desired and replace the cover as directed above.

CLEANING AND STORAGE

We recommend that you clean the air purifier at least once every 3 months and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier.

Do Not Use Water, Wax, Polish, Or Any Chemical Solution.

If your Air Purifier will not be used for more than 30 days, we recommend that you:

  • Remove the HEPA and Pre-Filter cartridge from the unit.
  • Wrap the HEPA and Pre-Filter cartridge in an air-tight plastic bag.

FREQUENTLY ASKED QUESTIONS

My Air Purifier is starting to make noise and the air output is less. What's wrong?

The filters may be dirty. High amounts of contaminants can block the pores in the filter and stop the air from moving through it. Replace the Filters. The HEPA Filters should be replaced every year and the Pre-Filter should be replaced every 3 months. Please note these are guidelines only and filters should be checked periodically as individual home conditions may vary. To ensure the unit continues to perform properly, replace with Genuine Honeywell Filters.

How long should I run my Air Purifier?

In general, the unit will be most effective when doors and windows are closed. It is recommended that you run your air purifier while you are at home to help clean the air. If desired or conditions warrant, you may run your air purifier 24 hours a day.

Can I wash any of the filters in my Air Purifier?

No. Washing the filters will ruin them.

What are VOCs?

Volatile Organic Compounds (VOCs) are emitted from various solids and liquids such as paints, cleaning supplies, building materials, and permanent markers. Some of these compounds can have adverse short and long term health effects and consistently have higher concentrations indoors than outside.

Why did my Air Purifier suddenly turn on a higher setting?

Is the air purifier set to Auto Mode? If it is, the unit may have sensed a higher level of VOCs and has adjusted the cleaning level accordingly.

CONSUMER RELATIONS

We are here to help. Call us toll-free at: 1-800-477-0457

E-mail: ConsumerRelations@HelenofTroy.com

Or visit our website at: www.HoneywellPluggedIn.com; In Canada visit: www.HoneywellPluggedIn.ca

Please be sure to specify the model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY.

IMPORTANT SAFETY INSTRUCTIONS

warning READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Read all instructions before operating the air purifier.
  2. Place air purifier where it is not easily overturned by persons in the household.
  3. ALWAYS turn the air purifier controls to the OFF position and unplug from the wall outlet when not in use.
  4. To disconnect the air purifier, make sure the unit is powered OFF then grip the plug and pull it from the wall outlet. NEVER pull by the cord.
  5. DO NOT use any product with a damaged cord or plug, any product that malfunctions, or any product that has been dropped or damaged in any manner. Keep the cord away from heated surfaces.
  6. DO NOT use air purifier outdoors.
  7. DO NOT use air purifier unless it is fully assembled.
  8. DO NOT run power cord under carpets, and DO NOT cover with throw rugs. Arrange cord such that it will not be a tripping hazard.
  9. DO NOT use air purifier where combustible gases or vapors are present.
  10. DO NOT expose the air purifier to rain, or use near water, in a bathroom, laundry area or other damp location.
  11. The air purifier MUST be used in its upright position.
  12. DO NOT allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air purifier. DO NOT block air outlets or intakes.
  13. Locate air purifier near the outlet and DO NOT use with extension cord or power strip.
  14. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  15. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  16. DO NOT sit, stand or place heavy objects on the air purifier.
  17. ALWAYS disconnect power supply before servicing.
  18. SAVE THESE INSTRUCTIONS.


TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS AIR PURIFIER WITH ANY SOLID-STATE SPEED CONTROL DEVICE.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.