Problem
An operating noise can
be heard after the appli-
ance has been switched
off.
Liquid has got into the
vapour extraction.
Extraction power has
decreased. Extraction
noise has increased.
The sensor control is
lit up.
The sensor control is
lit up.
The sensor control
does not light up.
Cause and remedy
The cooling fan runs until the hob has cooled down
and then switches off automatically.
Due to boiling over or spillage, liquid has made its
way through the cover grille into the vapour extrac-
tion.
The base of the grease filter and the drip tray can
hold approx. 800 ml of liquid in total.
Switch the vapour extraction off.
Clean the grease filter, the drip tray, the inside of
the casing and the fan motor compartment (see
"Cleaning and care").
KMDA 7676 FL-U only: replace the charcoal filter
(see "Cleaning and care – Replacing the charcoal
filter").
Objects (e.g. a cloth) have been drawn into the va-
pour extraction.
Switch the vapour extraction off.
Remove the grease filter (see "Cleaning and care –
Removing the grease filter").
Remove any objects from the grease filter.
The charcoal filter must be replaced.
Replace the charcoal filter (see "Cleaning and care
– Replacing the charcoal filter").
Reset the operating hours counter (see "Cleaning
and care – Resetting the charcoal filter operating
hours counter").
The grease filter must be cleaned.
Clean the grease filter as described in "Cleaning
and care – Grease filter".
The Con@ctivity function of the integrated vapour ex-
traction is permanently deactivated.
Activate the Con@ctivity function of the integrated
vapour extraction in the programming (see "Adjust-
ing settings").
Troubleshooting