Plug&Play with surface-mounted in-
stallation
Worktop depth 600 mm
KMDA 7676 FL-U
a The housing unit wall and an adjoin-
ing room wall or a piece of furniture
must be at least 25 mm apart to en-
sure sufficient room for the exhaust
air ducting.
b The removable drip tray and the
cleaning flap must be accessible
after installation.
c The cross-section of the ventilation
opening must be at least 425 cm².
Worktop depth greater than 600 mm
KMDA 7676 FL-U
a The housing unit wall and an adjoin-
ing room wall or a piece of furniture
must be at least 25 mm apart to en-
sure sufficient room for the exhaust
air ducting.
If the housing unit rear wall is
> 555 mm away from the front of the
worktop, the Plug&Play adapter
must be combined with an expan-
sion set from Miele.
b The removable drip tray and the
cleaning flap must be accessible
after installation.
c The cross-section of the ventilation
opening must be at least 425 cm².
x Dimension of which the worktop is
deeper than 600 mm.