hit counter script
Download Print this page
ABSCO SHEDS PREMIER 30232GK Assembly Instructions Manual

ABSCO SHEDS PREMIER 30232GK Assembly Instructions Manual

3.00mw x 2.26md x 2.00mh
Hide thumbs Also See for PREMIER 30232GK:

Advertisement

Quick Links

AU: 1800 029 701
N Z: 0800 466 444
For construction in non-cyclonic areas
Wind rating: "N2" as per AS4055-2021
("Medium M" to NZS3604-2011)
If you require a higher wind rating please contact us:
admin@absco.com.au or 1800 029 701
NOTE: This shed can be upgraded to wind rating:
"C1" as per AS4055-2021 ("Very High VH" to
NZS3604-2011) with the addition of a Cyclone Kit.
DOWNLOAD
OUR APP FOR
ASSEMBLY
VIDEOS
*Most models available
Absco Industries
Assembly Instruction Manual
ABSCO PREMIER SHED
MODEL: 30232GK
3.00mW x 2.26mD x 2.00mH
admin@absco.com.au
www.abscosheds.com.au
WHEN LAYING YOUR CONCRETE
SLAB, ENSURE THERE IS A
REBATED EDGE 25mm DEEP
AROUND THE PERIMETER
THIS WILL HELP WATER EGRESS
FROM THE BASE OF THE SHED
We thank you for choosing an Australian made
shed. For further assistance please visit our detailed
instructional video library at
Http://www.abscosheds.com.au/watch-videos
At ABSCO Industries we are always looking to be
number ONE, so please let us know what you think
of our instructions. Feedback makes us better.
feedback@absco.com.au
ABSCO INDUSTRIES
ASSEMBLY INSTRUCTION MANUAL
Absco Industries
Premier Shed Model: 23151GK
When laying concrete slab, ensure there
is a rebated edge 25mm deep around
the perimeter. This will help water egress
from the base of the shed.
PLEASE LEAVE A REVIEW
SHED MODEL: 23151GK
Tell us about your experience!
Visit www.abscosheds.com.au/review
Model: 30232GK
FRONT: 2.26m
SIDE:
HEIGHT: 1.95m
BOTTOM CHANNEL
REBATED EDGE
75mm WIDE REBATE
CONCRETE SLAB
21-11-2017
12/6/23
1.22
1.52m
PAGE 01
1

Advertisement

loading

Summary of Contents for ABSCO SHEDS PREMIER 30232GK

  • Page 1 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH AU: 1800 029 701 admin@absco.com.au N Z: 0800 466 444 www.abscosheds.com.au Absco Industries Premier Shed Model: 23151GK FRONT: 2.26m SIDE: 1.52m HEIGHT: 1.95m WHEN LAYING YOUR CONCRETE SLAB, ENSURE THERE IS A REBATED EDGE 25mm DEEP AROUND THE PERIMETER BOTTOM CHANNEL...
  • Page 2 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH GENERAL INSTRUCTIONS • Before commencing any assembly, read through these instructions in detail to gain a thorough understanding of assembly methods and associated details. • Unpack the carton and carefully identify and check off all the parts against the parts described and illustrated on "COMPONENTS PACKING LIST"...
  • Page 3 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH COMPONENT PACKING LIST Check off all components. COMPONENT PART COMPONENT PART CHECK CHECK DESCRIPTION DESCRIPTION STEEL SHEET STEEL SHEET 1785mm X 773mm 1725mm X 773mm (70.3" X 30.4") (67.9" X 30.4") STEEL SHEET STEEL SHEET 1785mm X 773mm...
  • Page 4 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH COMPONENT PACKING LIST PART COMPONENT PART COMPONENT CHECK CHECK DESCRIPTION DESCRIPTION 55AL 55AR CHANNEL CHANNEL L = 1496.5mm (58.9") L = 1496.5mm (58.9") 55CL 55CR CHANNEL CHANNEL L = 1496.5mm (58.9") L = 1496.5mm (58.9") 55BL 55BR...
  • Page 5 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH COMPONENT PACKING LIST COMPONENT PART COMPONENT PART CHECK CHECK DESCRIPTION DESCRIPTION JAMB L= 1785mm (70.3") JAMB L= 1120mm (44.1") LIP TRIM JAMB L= 1568mm (61.7") 1170mm (46.1") JAMB L= 1725mm (67.9") INSTRUCTIONS &...
  • Page 6 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH SNAPTiTE ASSEMBLY GUIDE The Snaptite Assembly System locks end channels to all roof and wall sheets without the need for tools and fasteners. To assemble each panel, the perimeter channels are secured to the top and bottom of each panel. Gently tap the channel over the SNAPTiTE lugs on the sheet, working along the sheet.
  • Page 7 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH Guide on Joining Spliced Channels The text marked on all parts must be shown on the same side as each other JOIN>> JOIN>> <<JOIN JOIN>> Step 1. Step 2. Position the channels and the Join the fi rst channel to the CSJ Push down one side of the CSJ CSJ joiner so the centre of...
  • Page 8 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH PRE-ASSEMBLY OF SPLICED CHANNELS Join together 20 x channel sections using 10 x channel joiners (Part CSJ) NOTE: Some channels may have holes in them - You will need to redrill holes where CSJ joining channel covers them.
  • Page 9 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH Guide on Joining a Spliced Ridge Beam If present, remove plastic coating from top side of ridge beam capping before assembly. Follow these three steps to assemble a ridge beam. ZARSP 225mm 50mm...
  • Page 10 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH PRE-ASSEMBLY OF SPLICED RIDGE BEAM ZARSP = 1x 97A 1x 97AL 1x 97AR Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 11 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH OVERVIEW OF ROOF COMPONENTS Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 12 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH OVERVIEW OF WALL COMPONENTS Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 13: Rear Panel Assembly

    ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH REAR PANEL ASSEMBLY 1x required. Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 14 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH ROOF PANEL ASSEMBLY 2x required. Fit 81A to edge of sheet with pre- punched holes. Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 15: Side Panel Assembly

    ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH SIDE PANEL ASSEMBLY 2x required. Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 16: Front Panel Assembly

    ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH FRONT PANEL ASSEMBLY 1x required. Absco Industries Assembly Instruction Manual Model: 30232GK 12/6/23 1.22...
  • Page 17: Door Panel Assembly

    ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH DOOR PANEL ASSEMBLY 1x required. Vertical door channels are installed in the opposite orientation compared to the horizontal door channels. Long Short fl ange fl ange of of channel channel Four hole set for padbolt connection.
  • Page 18 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH DOOR PANEL ASSEMBLY Nuts and bolts may be used instead of pop rivets by drilling out hinge holes using a 4mm drill bit. Both are supplied. The two holes required to connect the padbolt hasp for each door have not been pre-punched, to allow for proper alignment, position each hasp centrally over the padbolt shaft and drill 3mm holes and secure with screws.
  • Page 19 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH PANEL CONSTRUCTION NOTE: Take care to ensure that all wall panels are not upside down. The top channels of each panel are pre-punched for attaching roof sheeting. The base channels are not pre- punched.
  • Page 20 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH INSIDE VIEW OF FIXING Secure peak brace to Move the other roof ridge beam and roof panel into position and panel with one screw at secure peak brace to each end ridge beam with one screw at each end Absco Industries...
  • Page 21 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH FINAL CONSTRUCTION Bend the top and bottom flanges as shown, then hook the bottom flanges under the top channel and screw top to the ridge beam with two screws. ANCHORING OF SHED Location of 15 Bolt and Nut*...
  • Page 22 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH Absco Gable Roof Shed Notes General • 1.G This instruction manual shall be read in conjunction with other consultants drawings, specifi cations and written instructions provided by Absco and/or their representatives. •...
  • Page 23 ABSCO PREMIER SHED MODEL: 30232GK 3.00mW x 2.26mD x 2.00mH Absco Gable Roof Shed Notes Steelwork • 1.S All structural steelwork shall have a corrosion protection system applied consistent with AS/NZS 2312- 2002. • 2.S All structural steelwork detailed within this installation manual shall be minimum Grade •...
  • Page 24 Absco Sheds Storage Guidelines • Absco Sheds are designed to be weatherproof for normal weather conditions. In the event of extreme weather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins, screw fi xings etc., may exhibit minor deformations which may allow some water entry. These areas should be checked regularly to ensure that maximum strength and protection is maintained.
  • Page 25 Lifetime Warranty Statement 1. DEFINITIONS 3. WARRANTY CLAIM PROCEDURE In this document, capitalised terms have the following meaning: 3.1. If, during the Lifetime Warranty Period, You believe the Product has a “ABSCO” means John Scholtes Investments (No. 1) Pty Ltd trading Defect, You must comply with the procedure set out in this clause 3.
  • Page 26 4. WARRANTY LIMITATIONS / EXCLUSIONS 4.1. To the extent permitted by law, this warranty will not apply where: the Product has been installed or used for a purpose that is not an Authorised Purpose; the Product has not been installed, assembled, maintained and/or special, indirect or consequential loss or damage of any nature operated in complete compliance with ABSCO’s Product Guide;...