RE 93010-01-B/05.09 | A8VO Series 61 and 63
CAuTION!
6.4.6
Completing
assembly
1.
Remove any mounted transport screws.
2.
Remove the transport protection.
The axial piston unit was delivered with protective covers and plastic plugs or
locking screws. These must be removed before connecting. Use appropriate
tools.
3.
Make certain that the sealing and functional surfaces are not damaged.
Ports which are intended for connecting lines are provided with plastic plugs
or locking screws which serve as transport protection. If no connection is
made, these ports must be plugged with a suitable metal locking screw since
the plastic plugs are not pressure-proof.
Risk of personal injury and property damage!
Operating the axial piston unit with plastic plugs can result in injuries or damage
to the axial piston unit.
Before commissioning, remove all plastic plugs and replace them with
f
suitable, pressure-proof, metal locking screws.
2
1
Fig. 11:
Removing transport protection
1
Plastic transport protection for drive
shaft
2
Plastic protective covers (for
painted axial piston units, metal
protective covers are used)
The adjusting screws are protected against unauthorized resetting by means
of protective caps. Removal of the protective caps will void the warranty. If you
need to modify the setting, please contact your responsible Rexroth Service
(address as to chapter "9.5 Spare parts").
4.
For versions with power take-off, assemble the auxiliary pump according to
the pump manufacturer's instructions.
Bosch Rexroth AG
3
3
2
3
Plastic plugs / locking screws
4
For version with power take-off,
flange cover and fixing screws
27/52
Assembly
4
2