RE 93010-01-B/05.09 | A8VO Series 61 and 63
CAuTION!
CAuTION!
Changing plug position
Tightening torque for
HIRSCHMANN connector
6.4.8
Electrical connection of
The machine or system manufacturer is responsible for the layout of the electric
control.
For electrically controlled axial piston units, the electric control must be connected
according to the circuit diagram of the system manufacturer.
Missing seals and connections lead to noncompliance
with the protection class!
Fluids and contaminants may penetrate and damage the product.
Prior to assembly, make certain that all seals and connectors
f
Short circuit in event of penetrating hydraulic fluid!
Fluid can penetrate the product and cause a short circuit.
Do not install electrically controlled axial piston units in a tank below the tank
f
fluid level (tank installation).
1.
Switch off power supply to the relevant system component.
2.
Electrically connect the axial piston unit (12 or 24 V).
If necessary, you can change the position of the connector by turning the
solenoid.
To do this, proceed as follows:
2
1.
Loosen the fixing nut (
1
one turn counter-clockwise.
2.
Turn the solenoid body (
3.
Retighten the fixing nut. Tightening torque of the fixing nut: 5+1 Nm.
For further details and technical data, e.g. regarding the selection of a suitable
mating connector, refer to data sheet RE 93010.
On axial piston units with HIRSCHMANN connector, the following tightening
torques apply when securing wiring sockets:
•
Fixing screw M3 (
1):0.5
•
Cap nut M16 x 1.5 (
1
2
Fig. 15:
Tightening torque for HIRSCHMANN connector
Bosch Rexroth AG
the axial piston unit
1) of the solenoid. To do this, turn the fixing nut (1)
2) to the desired position.
2): 1.5–2.5 Nm
33/52
Assembly
are tight.