hit counter script

Hitachi HTS542525K9SA00 Specifications page 286

3.5 inch hard disk drive
Hide thumbs Also See for HTS542525K9SA00:
Table of Contents

Advertisement

Output Parameters To The Device
Feature Current
URG (bit7)
WC (bit6)
F (bit5)
HSE (bit4)
Stream ID (bit 0..2)
Feature Previous
Sector Count Current
Sector Count Previous
Sector Number Current
Sector Number Previous LBA (31:24).
Cylinder Low Current
Cylinder Low Previous
Cylinder High Current
Cylinder High Previous
URG specifies an urgent transfer request. The Urgent bit specifies that the
command should be completed in the minimum possible time by the device
and shall be completed within the specified Command Completion Time Limit.
WC specifies Write Continuous mode enabled. If the Write Continuous bit is
set to one, the device shall not stop execution of the command due to errors.
If the WC bit is set to one and errors occur in transfer or writing of the data, the
device shall continue to transfer the amount of data requested and then
provide ending status with BSY bit cleared to zero, the SE bit set to one, the
ERR bit cleared to zero, and the type of error, IDNF or ABRT reported in the
error log.
If the WC bit is set to one and the Command Completion Time Limit expires,
the device shall stop execution of the command and provide ending status with
the BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero,
and report the fact that the Command Completion Time Limit expired by setting
the CCTO bit in the error log to one.
In all cases, the device shall attempt to transfer the amount of data requested
within the Command Completion Time Limit even if some data transferred is in
error.
F specifies that all data for the specified stream shall be flushed to the media
before command complete is reported when set to one.
HSE (Handle Stream Error) specifies that this command starts at the LBA of
the last reported error for this stream, so the device may attempt to continue its
corresponding error recovery sequence where it left off earlier.
Stream ID specifies the stream being written.
according to the Stream ID set by the Write Stream command.
The time allowed for the current command's completion is calculated as
follows:
Command Completion Time Limit = (content of the Feature register
Previous) * (Identify Device words (99:98)) useconds
If the value is zero, the device shall use the Default CCTL supplied with a
previous Configure Stream command for this Stream ID. If the Default CCTL
is zero, or no previous Configure Stream command was defined for this Stream
ID, the device will ignore the CCTL. The time is measured from the write of the
command register to the final INTRQ for command completion.
The number of continuous sectors to be transferred low order, bits (7:0)
The number of continuous sectors to be transferred high order, bits (15:8). If
zero is specified in the Sector Count register, then 65,536 sectors will be
transferred.
LBA (7:0).
LBA (15:8).
LBA (39:32).
LBA (23:16).
LBA (47:40).
Deskstar 7K160 Hard Disk Drive Specification
272
The device shall operate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents