Example:
Output:
Access Control:
Per-Component Progress of a Firmware Upgrade Process
Displays per-component progress for the ongoing or most recently completed
firmware upgrade process
Shows per-component progress for the ongoing or most recently completed
firmware upgrade process. The following fields are displayed:
v Component ID: A component to be upgraded or already upgraded by the
v State: The upgrade state of the specific component. "On cooldown" means that
v Result: The result of the upgrade for the specific component. The result is
Id
value
xcli -u -c XIV1 component_firmware_upgrade_status
Name
Value
------------------
------------
last_process_start
2012-11-08 12:30:46
last_process_end
in_progress
yes
abort
no
abort_reason
firmware_type
disk
upgrade_type
hot
scope
1:Module:3
label
PREFERRED
current_timeout
120
current_cooldown
0
num_succeeded
7
num_failed
0
num_noops
0
User Category
Storage administrator
Storage integration administrator
Application administrator
Security administrator
Read-only users
Technicians
component_firmware_upgrade_progress
current process. Note that the component for USM upgrades is a module.
the upgrade has completed, but the process is waiting a predefined number of
seconds before proceeding with the next item, in order for the system to stabilize
itself.
available as soon as the component exits the "In progress" state.
Name
Value
Permission
Disallowed
Disallowed
Disallowed
Disallowed
Disallowed
Allowed
Chapter 20. Hardware Maintenance
Default Position
2
419