IBM 6H0 Service Manual page 116

Rs/6000 enterprise server
Hide thumbs Also See for 6H0:
Table of Contents

Advertisement

Step 1521-16
Note: Read the Danger and Caution notices under "Safety Notices" on page xi before
Perform the following:
1. Disconnect the mainline ac power cable from the customer's ac power outlet.
2. Use a multimeter to measure the ac voltage at the customer's ac power outlet.
Is the ac voltage from 200 V ac to 240 V ac?
NO
YES
96
Service Guide
continuing with this procedure.
Inform the customer that the ac voltage at the power outlet is not correct.
This ends the procedure. Go to "Map 0410: Repair Checkout" in the
Diagnostics Information for Multiple Bus Systems.
Replace the mainline ac power cable.
This ends the procedure. Go to "Map 0410: Repair Checkout" in the
Diagnostics Information for Multiple Bus Systems.