10 Servicing
D A N G E R
•
Check that the LED201 (red) located on the "W" surface PCB is OFF when opening the P-mounting plate.
•
Do not touch the electrical components when LED201 (Red) located on the "W" surface PCB is ON in order to
avoid an electrical shock.
Removing the coils for reversing and solenoid valve (SVA1 SVA2 and SVF)
1 Remove the service cover according to the section
2 Open the P-mounting plate according to the section
chapter.
1
1. PCB.
2. Upper cover.
3. Rear cover.
RAS-(4-6)HVRNM2E
•
1. PCN7 (SVA) Solenoid valve.
•
2. PCN6 (RVR) Reversing valve coil.
N O T E
•
Do not touch the electrical components when the LED201 (Red) located on surface "W" PCB is ON in order to
avoid electrical shock.
•
Remove the connectors on the control PCB of the electrical box.
•
Remove the reversing valve coil by removing the screw fixing the coil.
380
SMGB0064 rev.0 - 08/2011
Removing service
Opening electrical box (P-mounting
2
3
1. Reversing valve coil.
2. SVA.
1
2
•
1. PCN7 (SVA) Solenoid valve.
•
2. PCN6 (RVR) Reversing valve coil.
cover, see on page 372 in this chapter.
plate), see on page 379 in this
1
2
RAS-(4-6)HRNM2E
1
2