Page 1
® F o r T h e r m a d o r P r o f e s s i o n a l A l l G a s R a n g e s PG304 PG36 PG48...
Page 2
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these instructions for the Local Gas Inspector’s use. INSTALLER: Please leave these Installation Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. WARNING For Massachusetts Installations: Disconnect power before installing.
Model PG304 Model PG364GL Model PG484GG Low Back Model LB36R Low Back Model LB48R Contents Introduction ..........1 Important Installation Information ..... 2 Step 1: Ventilation Requirements ....3 Step 2: Cabinet Preparation ....4 – 8 Step 3: Unpacking, Moving and Placing the Range.......
2. The 36" ranges may be recessed into the cabi- nets beyond the edge of the front face of the a Thermador Island Trim may be used. (See Fig. oven (See Figures 2A and 2B). The 30" and 48" 2B). Figures 2A and 2B indicate the space ranges are not approved to be installed flush required for each type of backguard.
Page 7
Step 2: Cabinet Preparation CAUTION: Do not install the Models PG304 and PG48 ranges such that the oven door is flush with the cabinet face. A flush installation could result in damage to the cabinets due to exposure to high heat.
Page 8
Step 2: Cabinet Preparation FIG. 2A - Side View 3/8" FIG. 2B - Side View NOTE: For Island trim installations, counter surface should have a cantilever edge meeting the back section of the island trim accessory. 4" Cantilever Countertop NOTE: If an inner wall is used under the cantilever counter top, there 1/8"...
Page 9
Step 2: Cabinet Preparation GAS AND GAS SUPPLY ZONES: FIG. 3A Gas & Gas Supply Zone for All Gas Ranges The All Gas ranges may be con- nected to the power supply with a range supply cord (supplied Typical placement shown. with range) or by hard-wiring to Other placement of Gas Supply and Gas Recep-...
Step 2: Cabinet Preparation ELECTRICAL SUPPLY, ALL GAS RANGES Installation of All Gas ranges must be planned so that the rough-in of the junction box for the receptacle or conduit connection will allow maxi- mum clearance to the rear of the unit. This is especially critical if the junction box in the wall will be directly behind the junction box on the unit when the unit is installed.
Step 3: Unpacking, Moving and Placing The Range CAUTION Chart A 30" Range 36" Range 48" Range Proper equipment and ad- Shipping Weight 335 lbs. 444 lbs. 584 lbs. equate manpower must be used in moving the range to Weight without 285 lbs.
Step 3: Unpacking, Moving and Placing The Range • Due to the weight, a dolly with soft wheels Fig. 6- Dolly Positioning should be used to move this unit. The weight must be supported uniformly across the bot- tom (See Fig. 6). •...
Step 4: Installing Anti-Tip Device For all 30" and 36" ranges, an anti-tip device must be installed as per these instructions. WARNING WARNING RANGE TIPPING HAZARD • All ranges can tip and injury can result. To • ALL RANGES CAN prevent accidental tipping of the range, attach it to the floor, wall or cabinet by installing the Anti-Tip Device supplied.
Step 4: Installing Anti-Tip Device PG30 and PG36 All Gas Ranges (Figures 8A and 8B) Thermador Service Part No. Description 415078 Screw, Phillips, #10 x 1-1/2" 487310 Anti-Tip Bracket, Floor-Mounted IMPORTANT INSTALLATION INFORMATION: For walls or floors composed of drywall, sheet- •...
Step 5: Gas Requirements and Hookup HOOK UP Verify the type of gas being used at the installation site. As shipped from the factory, units are config- • A manual gas shut-off valve must be installed ured for use with natural gas or propane (LP) gas. external to the appliance, in an accessible loca- Make certain the range matches the type of gas tion from the front, for the purpose of shutting off...
Prior to servicing appliance, always disconnect appliance electrical supply cord from wall recep- tacle. Chart B: Electrical Supply Circuit Requirements MODEL NUMBER VOLTAGE CIRCUIT RATING FREQUENCY PHASE PG304 120 VAC 10 Amps 60 Hz. Single PG36 120 VAC 10 Amps 60 Hz.
(4) sheet metal screws pro- vided. Backguard Installed Chart C: BACKGUARD KIT MODEL NUMBERS RANGE MODEL NO. 9" STD. LOW BACK 12" LOW BACK 22" HIGH SHELF " ISLAND TRIM PG304 Included with Range HS30R IT30R PG36 LB36R HS36R IT36R PG48 LB48R...
Step 8: Door Installation CAUTION The door is heavy and requires two people to handle it properly. 1. Insert the door hinge into the hinge pocket in the front frame. When the door is properly installed, the bottom edge will be parallel to the front of the range and the hinge will click into position and support the weight of the door.
Step 9: Test and Adjustment Install any loose components, such sive noise, or lifting of the flame CAUTION as burner caps and grates, that from the burner. If any of these may have been removed earlier. conditions exist, check that the air Burner adjustments must be Be certain that burner caps seat shutter (grill and griddle only) or...
INSTALLER CHECKLIST ELECTRICAL FINAL CHECK LIST Grill components properly seated (not all models). Refer Placement of unit. Receptacle with correct over- to Use & Care Manual for Grill current protection is provided details. Specified clearances main- for service cord connection. tained to cabinet surfaces.
Page 24
Thermador indicating model number. We reserve the right to change specifications or design without notice. Note: These models are not currently certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada.