hit counter script

Connecting Terminals - Siemens SIDOOR AT40 System Manual

Automatic door control
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

6.1.3

Connecting terminals

Input line X1
X1 is the connection line to the power supply.
Connections
Cable type
Cable length
Connector(s)
Output line X2
X2 is the output line connecting to the SIDOOR controller.
Connections
Cable type
Cable length
Connector(s)
The rated data of the output are:
Rated output voltage
Rated output current
Continuous output power rating
Dangerous electrical voltage.
May cause death, serious injury or property damage.
The third line brought out at the output is only a functional grounding connection, this must
not be regarded or used as a ground in the sense of a PE connection!
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC
WARNING
L, N, PE 195 - 265 VAC
H05RN-F 3G1
2 m
Extruded protective Schuko-type socket,
10 / 16 A, 250 V AC, double-protected connecting
cable according to DIN 49.441, CEE7 / VII.
UA+, UA-, FE
H05RN-F 3G1
1.5 m
WAGO 721-103/026-045
36 V
2.5 A
<100 W
Power supply
6.1 SIDOOR NT40
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd400v

Table of Contents

Save PDF