hit counter script

Toro Greensmaster 3120 Service Manual page 201

Hide thumbs Also See for Greensmaster 3120:
Table of Contents

Advertisement

Testing the Starter Solenoid (continued)
Greensmaster 3120
17230SL Rev C
7. When testing is complete, secure the cables and wires to the solenoid.
Tighten the nuts on the solenoid coil posts from 15 to 20 in-lb (1.7 to 2.3
N∙m). Tighten the nuts on the main contact posts from 50 to 60 in-lb (5.7
to 6.8 N∙m).
8. Connect the positive (+) cable to the battery first and then connect the
negative (-) cable to the battery. Coat the wire and cable connections at the
battery and at the starter solenoid with
Battery Terminal Protector (page
Page 5–15
Electrical System: Testing the Electrical Components
5–3).

Advertisement

Table of Contents
loading

Table of Contents