Installation
4.1 Mechanical Installation
4.1
Mechanical Installation
Dimensions of the system
The converter has two frame sizes. Frame size A (FSA) and Frame size B (FSB), the
dimensions of each frame size is given in the figure and table below.
Figure 4-1
Dimensions of the converter
Table 4- 1
Converter dimensions
Frame size
A
B
Terminal housing dimensions and fixing points
The terminal housing of the G110M system replaces the existing terminal housing on the
connected motor. There are three different types of the terminal housings and they are
shown in the following figure. All three terminal housings have the same external
dimensions:
● Height: 92 mm.
● Width: 161 mm
● Depth: 171 mm
Please note that the fixing points (for securing the terminal housing to the motor) are
indicated in RED. The FS 80/90 terminal housing has six fixing points, two of which are
marked in GREEN and indicated by the ground symbol. These fixing points provide the
correct earthing between the terminal housing and the motor and MUST be used.
All fixing bolts for the terminal housing are supplied with each terminal housing.
38
H
L
(mm)
(mm)
135
270
135
309
D1
D2
(mm)
(mm)
208
216
208
216
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
D3
W (mm)
(mm)
without glands
161
132
181
132