Mounting
4.3 Mounting instructions
Table 4- 2
Is the geared motor free of visible damage?
Have the mounting surfaces (e.g. flange, shaft) on the customer machine and on the
motor been cleaned?
Are the mounting surfaces free of corrosion?
Do the mounting dimensions (e.g. shaft diameter, shaft length, true run) on the cus-
tomer machine meet the specification?
Is the supplied mounting paste available for mounting the 1FG1 with hollow shaft or
with splined shaft?
Is the point of power transmission between the customer's hollow shaft and the geared
hollow shaft free of grease, mounting paste and other contamination when mounting
the 1FG1 with shrink disks or SIMOLOC connection? (See chapter Mounting or re-
moving the hollow shaft with shrink disk (Page 91) or Installing or removing the
SIMOLOC connection (Page 95))
4.3
Mounting instructions
Note
Technical data on the housing of the servo geared motor
• Comply with the technical data on the rating plates on the housing of the servo geared
motor.
● Comply with the data on the rating plate, as well as the warning and information plates on
the servo geared motor.
● Check the permissible ambient conditions (e.g. temperature, installation altitude) at the
installation location.
● Their use is prohibited in hazardous zones and areas.
● Thoroughly clean the shaft extension of corrosion protection. Use commercially available
solvents.
● Ensure sufficient dissipation of heat (see chapter "Cooling (Page 31)").
● If the motor is installed vertically with the end of the shaft facing up, ensure that no liquid
can enter the upper bearing.
● After installation, remove the lifting eyes or tighten them.
80
Checklist (2) - checks regarding the mechanical system
Check
Operating Instructions, 07/2019, A5E47360747B AA
SIMOTICS S-1FG1 servo geared motor
OK