Chapter 17
DLPs H100 to H199

DLP-H175 Clean Fiber Connectors with CLETOP

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Remove the dust cap from the fiber connector.
Step 1
Press the lever down to open the shutter door. Each time you press the lever, you expose a clean wiping
Step 2
surface.
Insert the connector into the CLETOP cleaning cassette slot, rotate one quarter turn, and gently swipe
Step 3
downwards.
Use an inspection microscope to inspect each fiber connector for dirt, cracks, or scratches. If the
Step 4
connector is not clean, repeat Steps
Insert the fiber connector into the applicable adapter or attach a dust cap to the fiber connector.
Step 5
Note
Step 6
Return to your originating procedure (NTP).

DLP-H176 Clean the Fiber Adapters

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Remove the dust plug from the fiber adapter.
Step 1
Insert a CLETOP stick swab (14100400) into the adapter opening and rotate the swab.
Step 2
Place dust plugs on the fiber adapters when not in use.
Step 3
Return to your originating procedure (NTP).
Step 4
78-19416-01
This task cleans the fiber connectors with CLETOP.
Type A fiber optic connector cleaner (CLETOP reel)
Optical receiver cleaning stick
None
As needed
Onsite
None
If you must replace a dust cap on a connector, first verify that the dust cap is clean. To clean the
dust cap, wipe the outside of the cap using a dry lint free wipe and the inside of the dust cap
using a CLETOP stick swab (14100400).
This task cleans the fiber adapters.
CLETOP stick swab
None
As needed
Onsite
None