HUAWEI USG6000 Unified Security Gateway
Hardware Guide
Step 3 Run the reset raid primary-disk disk-id command in the system view to create the RAID on
the primary disk and synchronize data. In this example, run the reset raid primary-disk 0
command. Several hours later, run the display disk information command. If Filesystem
Status is Mounted and DiskRaidMode is ACTIVE, both hard disks work properly.
After the RAID is created, the data in the primary disk will be synchronized to the secondary
disk and the original data on the secondary disk will be overwritten. Select the disk-id of the
primary disk before creating RAID.
----End
Follow-up Procedure
Send the faulty hard disk unit to EdgeWave for repair.
3.3 Replacing a Power Module
This section describes how to replace a faulty power module.
Issue 03 (2015-01-26)
Figure 3-6 Adding the hard disk unit
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Maintaining the Hardware
234