Sign the Site Acceptance Test report.
8
L
S
EAVING
Before Leaving Site:
•
Check that the clock is correctly set.
•
Check current plan. If CLF is configured, use the user interface to verify that
the correct plan is in operation bearing in mind time of day.
•
CLF and timetable can be re-synchronised with the real time clock using the
user interface.
•
Reset any data that has been set up for testing, e.g. permanent demands or
extensions.
•
If all inputs can be reset to normal operation, i.e. none have been set to
provide permanent signals due to faulty inputs, then use the user interface to
reset all inputs to normal operation.
•
Select 'Normal' on Manual Panel (unless there is a valid reason to leave it in
'Fixed Time', for example)
•
Should manual control be enabled, use the user interface to enable or disable
manual control.
•
If all faults have been investigated the fault log may be cleared using the user
interface.
•
If MOVA or UTC are enabled, ensure that they are functioning as expected.
•
Ensure the visit is accurately recorded in the controller's `visit log book'. It
should contain reason for visit, action taken (i.e. PCB changed etc.) and any
follow up action required or details of what actions are required should the
fault recur.
•
Place the Junction Plan, the IC4 Printout and the Site Logbook into the pocket
inside the door of the controller.
•
Lock the Manual Panel door, ensure that the main controller door is locked
and return the keys to the customer.
9
R
OUTINE
This section contains a list of checks to be performed at an ST950 installation on a
regular basis (normally annually).
These instructions override any others that may exist. If a Site PI exists for the
specific site, it may contain instructions that should be carried out in addition to
those detailed below.
Security classification
Version
Last Editor
Document Name
Copyright © Siemens Mobility Limited 2018. All Rights Reserved.
ITE
The key lock should not be operated unless the screw locks are tight,
i.e. Unlock the case before undoing the screw lock and only lock the
case after tightening the screw locks.
M
P
AINTENANCE