Page 2
Copyright All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. ® Copyright ABB EV Infrastructure. All rights reserved. BCM.S1101.0-EN | 001...
Contents Contents About this document................6 Function of this document....................6 Target group........................6 Revision history........................6 Language..........................6 Illustrations......................... 6 Units of measurement......................6 Typographical conventions....................6 How to use this document....................7 General symbols and signal words..................7 1.10 Special symbols for warnings and dangers................ 8 1.11 Related documents......................8 1.12...
Page 4
Contents Personal protective equipment..................19 Safety instructions for use....................19 Safety instructions during cleaning or maintenance............20 Safety instructions for earthing..................20 Signs on the EVSE......................20 Discard parts or the EVSE....................21 Operation.................... 22 Prepare before use......................22 Stop the EVSE if there is an emergency................22 Reset the EVSE after an emergency................22 Charge session.........................23 4.4.1...
Page 5
Contents Floor space requirements....................35 Ambient conditions......................36 Noise level........................36 Logic interface specifications....................36 7.10 DC output specifications....................37 7.10.1 General specifications..................37 7.10.2 Terra 94......................37 7.10.3 Terra 124......................39 7.10.4 Terra 184......................40 7.11 Power consumption......................42 7.11.1 General specifications..................42 7.11.2 Terra 94......................42 7.11.3...
About this document About this document Function of this document The document is only applicable for this EVSE (Terra x4), including the variants and options listed in section The document gives the information that is necessary to do these tasks: •...
About this document How to use this document 1. Make sure that you know the structure and contents of this document. 2. Read the safety chapter and make sure that you know all the instructions. 3. Do the steps in the procedures fully and in the correct sequence. 4.
About this document Signal word Description Symbol Make sure that the power supply to the EVSE is disconnected. Electrotechnical expertise is required, ac- cording to the local rules. Note: It is possible that not all symbols or signal words are present in this document.
ABB EV Infrastructure Heertjeslaan 6 2629 JG Delft The Netherlands Contact data The local representative of the manufacturer can give you support on the EVSE. You can find the contact data here: https://new.abb.com/ 1.13 Abbreviations Abbreviation Definition Alternating current Controller area network...
About this document Term Definition Grid provider Company that is responsible for the transport and distribu- tion of electricity Local rules All rules that apply to the EVSE during the entire lifecycle of the EVSE. The local rules also include the national laws and regulations.
Max xxxA DC Output 2 CHAdeMO xxx-xxxV Max xxxA George Hintzenweg 81, 3068 AX Rotterdam, IP54 The Nederlands MADE IN ITALY www.abb.com Manufacturer EVSE rating Serial number Address of the manufacturer Part number of the EVSE CE mark Production date...
Description Danger: General risk • If you use the EVSE in any other way than described in the related documents, you can cause death, injury and damage. • Use the EVSE only as intended. Overview 2.3.1 Overview of the system AC input cable Parking space Power distribution board...
Description 2.3.2 Overview of the EVSE, outside Left door Emergency stop button Type plate Touchscreen Air inlet Front door Cover on the air outlet Enclosure Border cover Antenna EV charge cable outlet and holder (1x Right door or 2x) Air outlet Plate over the RFID reader and the integrated payment terminal Part...
Description Part Function Enclosure To reduce the accessibility of unqualified persons to the inside of the EVSE Antenna To send and receive wireless 2G, 3G and 4G signals 2.3.3 Overview of the EVSE, inside Main breaker 2 Cable gland plate Main breaker 1 Manual switch PE busbar...
The touchscreen guides the user how to use the payment terminal. Note: • To use and adjust the settings of the payment terminal, you require the ABB Payment Web tool. CCV or Nayax . If • The standard payment terminal is from manufacturers you need more information about different options for payment terminals, ask ABB EV Infrastructure.
Description 2.6.2 General description of the buttons Button Name Description Connector To select the connector. • X = Charge power • Y = Connector location • Z = Type of connector Information To show more information about the EVSE Help To show help information on the current status of the EVSE...
Safety Safety Liability The manufacturer is not liable to the purchaser of the EVSE or to third parties for damages, losses, costs or expenses incurred by the purchaser or third parties if any target group mentioned in the related documents does not obey the rules below: 1.11 •...
Safety • Know and implement the local rules. • Identify the hazards (in terms of a risk assessment), resulting from the working conditions on the site. • Operate the EVSE with the protective devices installed. • Make sure that all protective devices are installed after installation or maintenance work.
Safety Safety instructions during cleaning or maintenance Preliminary requirements • • Keep unauthorized personnel at a safe distance during cleaning or maintenance. • If for cleaning or maintenance it is necessary to remove safety devices, immediately install the safety devices after the work. •...
Safety Symbol Risk type Sign that means that you must read the manual before you install the EVSE Waste from electrical and electronic equipment Note: It is possible that not all symbols are present on the EVSE. Discard parts or the EVSE •...
Operation Operation Prepare before use 1. Appoint a site operator and an installation engineer, if these are other persons than you. 2. Make sure that the EVSE is installed according to the instructions in the installation manual. 3. Make an emergency plan that instructs people what to do in case of an emergency. 4.
Operation Charge session 4.4.1 Charge an EV 1. Park an EV in the parking space. Make sure that the connector of the EV charge cable can reach the connector on the EV. 2. De-energize the EV. 4.4.2 3. Start the charge session. Refer to section 4.
Operation Energize the EVSE 1. Open the front door. Refer to section 1 position (vertical). 2. Set the manual switch to the Warning: General hazard • Be careful and use both your hands to turn the manual switch. You need some force to turn the switch. 3.
Operation • Voltage tester Procedure 1. Measure the AC voltage between the terminals on the surge protection device switch: R, S and T to N • R to S • R to T • S to T • Use the voltage tester. R, S, T Note: The surge protection device switch shows the indications 4.6.3...
Operation 1. Open the front and right doors. Refer to section 2. Set the main breakers 1 and 2 to the off position: Auto to the Manual position. a. Set the main breakers from the Manual to the Off position. b.
Operation Note: When the EVSE is put in a corrosion sensitive environment, superficial rust is possible on welding points. This rust is only visual. There is no risk for the integrity of the cabinet. The procedure below removes the rust. Procedure 1.
Operation Procedure 1. De-energize the EVSE. Refer to section 2. Open the left and right doors. Refer to section 3. Loosen the nuts (A). Use the spanner. 4. Carefully remove theses parts: 1. Cover (B) 2. Air inlet filter (C) Caution: Prevent contamination of other parts of the EVSE.
Page 29
Operation 9. Do the steps 3 to 8 again for the other air outlet filters. 10. Close the doors. Refer to section BCM.S1101.0-EN | 001...
Troubleshooting Troubleshooting Troubleshooting procedure 1. Try to find a solution for the problem with the aid of the information in this document. 2. If you cannot find a solution for the problem, contact your local representative of the 1.12 manufacturer. Refer to section Troubleshooting table Problem Possible cause...
Access to parts Access to parts Open the doors Preliminary requirements • Door key Note: There is one unique door key for each cabinet. Procedure 1. Unlock the lock (A) of the front door (B). Use the door key. 2. Open the front door. 3.
Page 32
Access to parts Procedure 1. If the left or right doors (A) are open, close the doors through the opening of the front door. 2. Close the front door (B). 3. Lock the lock (C) of the front door. Use the door key.
Two CCS connec- tions One CCS connection and one ChadeMo connection Example Terra 94 C: • T = Terra, Brand = Terra • U = 9, Power rating = 90 kW • V = 4, Design generation = fourth generation •...
XUF.N0001.0 Air outlet filter XUF.N0002.0 Cooling fan ZFV.V2N00.0 Power module YPA.00267 3 x Terra 94 4 x Terra 124 6 x Terra 184 DC fuse 500 A ZEG.00132 1 x Terra x4 C 2 x Terra x4 CC/CJ/JJ CPI Combo CCS YVD.V39A3.0...
Technical data Part Name Part number Quantity Auxiliary power supply YPA.00205 CCS connector and cable ZLH.01085 1 x Terra x4 C/CJ 2 x Terra x4 CC CHAdeMO connector and YVD.V3G25.0 1 x Terra x4 CJ cable 2 x Terra x4 JJ Gun holder XAB.V2N21.0 1 x for CCS type 1 UL con-...
Technical data Cabinet Total depth Total width Space to open the front door Space for air inlet and to open the left Space for air outlet and right doors Parameter Specification [mm] 1550 1460 Ambient conditions Parameter Specification Environment, general Indoor and outdoor Storage temperature -40°C to +70°C...
DC output voltage range, CHAdeMO 150-500 V DC Minimum DC output current 15 A Connection standard CHAdeMO 1.2 7.10.2 Terra 94 Parameter Specification DC output power, mode 1, continuously on Maximum 90 kW one EV charge cable Simultaneous DC on two outlets No.
Page 38
Technical data Output current in function of output voltage 1000 Output current [A] Output voltage [V] Output power in function of output voltage 1000 Output power [kW] Output voltage [V] BCM.S1101.0-EN | 001...
Technical data 7.10.3 Terra 124 Parameter Specification DC output power, mode 1, continuously on Maximum 120 kW one EV charge cable DC output power, mode 2, continuously on Maximum 60 kW two EV charge cables Simultaneous DC on two outlets Yes.
Technical data Output power in function of output voltage 1000 Output power [kW] Output voltage [V] 7.10.4 Terra 184 Parameter Specification DC output power, mode 1, continuously on Maximum 180 kW one EV charge cable DC output power, mode 2, continuously on Maximum 90 kW two EV charge cables Simultaneous DC on 2 outlets...
Page 41
Technical data Output current in function of output voltage 1000 Output current [A] Output voltage [V] Output power in function of output voltage 1000 Output power [kW] Output voltage [V] BCM.S1101.0-EN | 001...
Note: The heater will operate daily when the outside air reaches the dew point, to avoid condensation inside the cabinet. When the heater operaters, the heater will use most of the required standby power. 7.11.2 Terra 94 Parameter Specification [kVA) Power consumption during normal opera- tion 7.11.3...