INSTRUCTION MANUAL
D1xB2X05-S, D1xB2X10-S, D1xB2X15-S
Xenon Beacons – SIL2
For use in Hazardous Locations
1) Warnings
• DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
• DO NOT OPEN WHEN ENERGISED
• POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
• HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
• DO NOT PAINT
• TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, THE FIRST
CONDUIT RUN MUST HAVE A SEALING
FITTING CONNECTED WITHIN 18 INCHES
OF ENCLOSE. SUBSEQUENT CONDUIT
RUNS MUST HAVE A SEALING FITTING
CONNECTED AS CLOSE AS PRACTICAL TO
THE WALL OF THE ENCLOSURE, BUT IN
NO CASE MORE THAN THE SIZE OF THE
CONDUIT OR 50MM, WHICHEVER IS THE
LESSER.
• TO PREVENT IGNITION OF GROUP A, B, C
AND D ATMOSPHERES - SEE
INSTRUCTION FOR CHEMICAL
COMPATIBILITY
Avertissement:
• NE PAS OUVRIR UN PRESENCE
D'ATMOSPHERE EXPLOSIVE
• NE PAS OUVRIR ENERGIE
• DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
• HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L'ALIMENTATION AVANT
D'OUVRIR LA BOITIER
• NE PAS PEINTURER
• POUR RÉDUIRE LE RISQUE
D'INFLAMMATION DES ATMOSPHÈRES
DANGEREUSES, LE PREMIER CONDUIT DE
CONDUIT DOIVENT AVOIR UN RACCORD
D'ÉTANCHÉITÉ RACCORDÉ À MOINS DE 18
E2S Warning Signals
Impress House, Mansell Road, Acton, London W3 7QH
Document No. D191-00-621-IS
Issue 1
27-10-22
D1xB2X05-S
D1xB2X10-S
D1xB2X15-S
POUCES DE L'ENFERMEMENT. POUR
SUBSÉQUENT LES CONDUITES DE
CONDUIT LA DISTANCE ENTRE LA
SURFACE DE LA MASSE DE REMPLISSAGE
AU PLUS PRÈS DE L'ENVELOPPE DOIT
ÊTRE AUSSI PETITE QUE CE QUI EST
RÉALISABLE MAIS EN AUCUN CAS
SUPÉRIEURE À LA PLUS PETITE DES
DIMENSIONS CORRESPONDANT À LA
TAILLE DU CONDUIT OU À 50 MM.
• POUR PRÉVENIR L'INFLAMMATION DES
ATMOSPHÈRES DES GROUPES A, B, C ET
D-VOIR L'INSTRUCTION POUR LA
COMPATIBILITÉ CHIMIQUE
2) Rating & Marking Information
2.1 Fire Alarm Ratings
The Following models are certified as visual alarm devices for
fire alarm use – private mode only when used with Clear or
Red lens covers:
D1xB2X05DC024 / D1xB2X10DC024 / D1xB2X15DC024
On-axis light output per UL1638:
Model
D1xB2
X05DC024-S - 1Hz
X05DC024-S - 1.33Hz
X05DC024-S - 1.5Hz
X10DC024-S - 1Hz
X10DC024-S - 1.33Hz
X10DC024-S - 1.5Hz
X15DC024-S - 1Hz
X15DC024-S - 1.33Hz
X15DC024-S - 1.5Hz
www.e2s.com
Light Intensity in cd
Clear Lens
Red Lens
20.44
5.89
14.47
4.17
11.1
2.13
69.81
23.66
49.42
16.75
35.71
8.57
98.61
31.83
69.81
22.53
50.44
11.53
Tel: +44 (0)208 743 8880
Sheet 1 of 15

Advertisement

Table of Contents
loading

Summary of Contents for E2S D1xB2X05-S

  • Page 1 INSTRUCTION MANUAL D1xB2X05-S, D1xB2X10-S, D1xB2X15-S Xenon Beacons – SIL2 For use in Hazardous Locations D1xB2X05-S D1xB2X10-S D1xB2X15-S POUCES DE L'ENFERMEMENT. POUR 1) Warnings SUBSÉQUENT LES CONDUITES DE CONDUIT LA DISTANCE ENTRE LA • DO NOT OPEN WHEN AN EXPLOSIVE SURFACE DE LA MASSE DE REMPLISSAGE ATMOSPHERE IS PRESENT AU PLUS PRÈS DE L’ENVELOPPE DOIT...
  • Page 2 Installation must be carried out in compliance with the National Electric Code / Canadian Electric Code Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 2 of 15...
  • Page 3 Gas Groupings: Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 3 of 15...
  • Page 4: Special Conditions Of Use

    The installation of the units must also be in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer who has the necessary training. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 5: Cable Connections

    Minimum resistance 3K3 Ohms Minimum Power 0.5W Minimum resistance 470 Ohms Minimum Power 2.0W Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 5 of 15...
  • Page 6 External Earth Stud Internal Earth Terminal Figure 6: Internal and External Earth Locations. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 6 of 15...
  • Page 7: Maintenance, Overhaul & Repair

    The Beacon lens cover is interchangeable, contact E2S Ltd for a replacement lens cover available in various colours. To change the lens cover, unscrew the 4-off M5 socket head screws, spring and flat washers using a 4mm Hex key.
  • Page 8 Active mode. be closed contact between terminals 1 & 2. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 8 of 15...
  • Page 9 If the hard reset process does not correct the latched fault the alarm horn sounder may require further investigation, please contact your local E2S representative. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com...
  • Page 10 Power & Communication with the system control panel can be configured in two ways: - Although it is highly recommended that the unit is wired as stated in section 17-1 as a 4-Wire System. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 10 of 15...
  • Page 11 If multiple SIL 2 alarm horn sounders are to be cabled in series, the monitoring connections differ from that of a single beacon. For more information see manual D197-00-621-IS available from the E2S website. 17-2) SIL 2 System Wiring for Fault Detection in Standby Mode Only – 2 Wire Installation Cabling is required to the positive '+' and negative '-' power input terminals only.
  • Page 12 If multiple SIL 2 alarm horn sounders are to be cabled in series, the monitoring connections differ from that of a single beacon. For more information see manual D197-00-621-IS available from the E2S website. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com...
  • Page 13 Hard Reset Enabled - Active reset mode. Figure 15: J7 Header pin positions – Hard Reset Function Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22 Sheet 13 of 15...
  • Page 14 All D1xB2 SIL2 beacons that are connected to the same supply line will have a synchronised flash rate at one flash every second. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 E2S Warning Signals Document No. D191-00-621-IS Issue 1 27-10-22...
  • Page 15 The alternative 2-wire configuration requires an EOL resistor to be fitted. The EOL resistor can be specified during ordering and factory fitted or selected and fitted during the beacon installation. See section 9 for EOL resistor location and wattage requirements. E2S recommends a value of 2.2K Ohm. If an alternative value is required, please see section 17-2.
  • Page 16 BEACON WIRING DIAGRAM WRITTEN CONSENT. IMPRESS HOUSE 23/09/2022 B.ISARD STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET ALTERNATIVE MATERIAL APPROVED DATE WWW.E2S.COM D191-06-621 NTS 1 23/09/2022 R.N.POTTS...
  • Page 17: Eu Declaration Of Conformity

        Manufacturer:      European Safety Systems Ltd.        Impress House, Mansell Road, Acton        London, W3 7QH        United Kingdom    Authorised Representative:  E2S Warnsignaltechnik UG        Charlottenstrasse 45‐51        72764 Reutlingen        Germany      Equipment Type:   D1xB2X05, D1xB2X10, D1xB2X15, D1xB2X21, D1xB2LD2, D1xJ2    Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX)  Notified Body for EU type Examination (Module B): ...
  • Page 18 II 2G Ex d IIC T6…T3 Gb  II 2D Ex tb IIIC T95°C…T169°C Db   Standards applied:  EN 60079‐0:2018  EN 60079‐1:2014  EN 60079‐31:2014  IP6X Dust Protection to EN60079‐0 / EN60079‐31  Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)   Standards applied:  EN 61000‐6‐1:2007  EN 61000‐6‐2:2005  EN 61000‐6‐3:2007 / A1:2011 / AC: 2012  EN 61000‐6‐4:2007 / A1: 2011  Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)  The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic    equipment, including amendment by Directive 2015/863/EU. Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)  The product and all the components contained within it are free from substances of very high concern.  Other Standards and Regulations  EN 60529:1991 + A1:2000 + A2:2013. ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67    On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment  conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.      This Declaration is issued under the sole responsibility of the manufacturer.       Martin Streetz  Document No.:  DC‐096_Issue_A  Quality Assurance Manager  Date and Place of Issue:  London, 24/02/2022      E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com  DC‐096_Issue_A ‐ Page 1 of 1 ‐ QAF_252_Issue_5...

This manual is also suitable for:

D1xb2x10-sD1xb2x15-sD1xb2x10D1xb2x05

Table of Contents