■1134H (4404) Diagnostic alarm
Do not change the default value (0).
■1135H (4405) Output behaviour on fieldbus error
The setting is the same as that from the NZ2FT-MT parameter "Output behaviour on fieldbus error".
Set the output operation when a fieldbus error or an error of Reference list occurs.
Value
Description
0
All outputs are 0.
1
All outputs are Substitute value.
2
All outputs hold the previous Process value.
■1136H (4406) Module behaviour on hot swap
The setting is the same as that from the NZ2FT-MT parameter "Module behaviour on hot swap".
When 0 is set, Process data communications continue.
When 1 is set, the operation follows the setting when a fieldbus error occurs.
■1137H (4407) Data format
The setting is the same as that from the NZ2FT-MT parameter "Data format".
When 0 is set, the data will be transferred in big endian (Motorola format).
When 1 is set, data is transferred in little-endian (Intel format).
■113CH to 113DH (4412 to 4413) Boot module parameters
These parameters are for loading (LOAD) the default parameters of all I/O modules. The parameters are the same as those of
the NZ2FT-MT below.
• Set "Default" to "Save module parameter on coupler".
• Select "Restore default values" from the "Module parameters" menu.
Write and set the string "LOAD".
Item
String
ASCII (decimal)
ASCII (hexadecimal)
Hexadecimal
Decimal
■113EH to 113FH (4414 to 4415) Save module parameters
These parameters are for recording (SAVE) Module parameters (C000H to FFFFH) of all I/O modules in the non-volatile
memory of the NZ2FT-MT.
Even if the parameter settings are changed after recording, the recorded parameter settings will be used to operate when the
NZ2FT-MT is reset.
The parameters are the same as those of the NZ2FT-MT below.
• Set "Yes" to "Save module parameter on coupler".
• Select "Save module parameters" from the "Module parameters" menu.
Write and set the string "SAVE".
Item
String
ASCII (decimal)
ASCII (hexadecimal)
Hexadecimal
Decimal
Big endian (Motorola format)
113CH
113DH
L
O
A
76
79
65
4CH
4FH
41H
4C4FH
4144H
19535
16708
Big endian (Motorola format)
113EH
113FH
S
A
V
83
65
86
53H
41H
56H
5341H
5645H
21313
22085
Little endian (Intel format)
113CH
D
D
A
68
68
65
44H
44H
41H
4441H
17473
Little endian (Intel format)
113EH
E
E
V
69
69
86
45H
45H
56H
4556H
17750
11.7 MODBUS Standard Functions and MODBUS Devices
11
113DH
O
L
79
76
4FH
4CH
4F4CH
20300
113FH
A
S
65
83
41H
53H
4153H
16723
11 NZ2FT-MT
317

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents