FINAL iNSTALLATiON CHECKLIST
,, At least 36" (91=cm) clearance
must be maintained
from combustible
constructions
to the
sides and back of the grill.
,, There is no combustible
construction
material over the grill.
,, All internal packaging
is removed.
,, Burners are sitting properly on orifices. The orifice of the valve must be located in the center
of the burner section after removal and cleaning. Otherwise,
it may cause serious bodily injury
and property damage. Swing the burner slightly after replacing to check whether it has been
installed properly.
,, Knobs turn freely.
,, The regulator and hose connected
to the grill are provided
by the manufacturer
(preset for
11" [28-cm] water column).
,, Unit tested and free of leaks.
,, User informed of gas supply shut-off valve location.
GRILL LIGHTING INSTRUCTION
VERY IMPORTANT:
ALWAYS INSPECT
THE HOSE PRIOR TO EACH USE.
BEFORE
LIGHTING:
,, Inspect the gas supply hose before turning the gas ON. If there is evidence of cuts, wear,
or abrasion,
it must be replaced
before use. The replacement
hose assembly
must be that
specified
by the manufacturer.
TO LIGHT MAIN BURNERS OF THE GRILL:
Read instructions
before
lighting.
_
...............
1. Open the lid and make sure all knobs are in the "OFF" position.
2. Push and turn the knob slowly counterclockwise
to the ignite
_
position
( @ ) as shown in Fig. 11. Keep pushing until the burner
lights and then release. Repeat for additional
burners.
3. If burner does not light, immediately
turn the control knob to
Fig. 11
the "OFF" position and repeat Step 2.
4. If burner does not light after Step 3, TURN OFF GAS SUPPLY and WAIT 15 MINUTES for the
gas to disperse; then repeat Steps 1 and 2 or light with external flame.
Shutdown
instructions:
1. Turn all control knobs to the "OFF" position.
2. Turn gas supply off at the tank.
24