[Setting example]
After power ON, changing from 0.00 display to change the b083 (carrier frequency) data.
Press [ESC] key to show
the function code
d001
ESC
Press [ESC] key to move
on to the function group
F001
ESC
Press [ESC] key twice to move
on to the function group b001.
b001
function code
b083
Press up key to increase the
data
(5.0
When data is changed, the display
starts blinking, which means that new
data has not been activated yet.
SET
:Fix and stores the data and moves back to the function code
:Cancels the change and moves back to the function code
ESC
Function code dxxx are for monitor and not possible to change.
Function codes Fxxx other than F004 are reflected on the performance just after changing the data
(before pressing SET key), and there will be no blinking.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Data of
display after the first power ON
ESC
0.00
SET
F001
Press Up key to change increase
b083)
(b001
Press SET key to display the data of
SET
Display is solid lighting.
ESC
12.0)
SET
12
Press SET key to set
and save the data
d001
will be shown on the
b083
5
0
.
0
.
17

Hide quick links: